This handout teaches D.4 Induction in full, for the course first assessed in 2025. The whole unit is additional higher level (AHL); there is no SL counterpart.
Prerequisites: magnetic field lines and the force on a current-carrying conductor from D.2 and D.3; emf and circuits from B.5; energy conservation from A.3; sine curves and angular velocity $\omega = 2\pi f$ from A.2 and C.1.
19.2
AHL:磁通量
English
How does a phone charge without a cable?
Put a phone on a wireless charging pad and it starts charging, although no wire joins them. A coil in the pad carries an alternating current, so the magnetic field through a second coil inside the phone keeps changing. A changing magnetic field through a coil makes an emf in it, and that emf drives the charging current. The same idea runs power-station generators, transformers, electric guitar pick-ups, induction cookers and the brakes of some trains. This unit explains how it works.
Changing flux links two coils
Flux through an area
For a uniform field through a flat area, the signed magnetic flux 磁通量$\Phi$ is the normal component of magnetic flux density multiplied by area:
$$\Phi = BA\cos\theta$$
where $B$ is the magnetic flux density and $\theta$ is the angle between the field and the normal 法线 to the area (the line at right angles to the surface).
The unit of flux is the weber 韦伯 (Wb): $1\ \text{Wb} = 1\ \text{T m}^2$.
The flux is greatest ($\Phi = BA$) when the field passes straight through the area ($\theta = 0$).
The flux is zero when the field runs along the surface ($\theta = 90°$).
Only the part of the field along the normal passes through the coil
Choose and retain one surface normal; reversing the field reverses the flux sign. For a coil of $N$ turns each linking the same flux $\Phi$, the product $N\Phi$ is called the flux linkage 磁链 and is measured in Wb (sometimes written Wb-turns).
Worked examples
A coil of area $2.0 \times 10^{-3}\ \text{m}^2$ lies at right angles to a field of 0.20 T. $\Phi = 0.20 \times 2.0 \times 10^{-3} = 4.0 \times 10^{-4}\ \text{Wb}$.
The coil is turned so its normal is at 60° to the field. $\Phi = 4.0 \times 10^{-4} \times \cos 60° = 2.0 \times 10^{-4}\ \text{Wb}$.
If it has 150 turns, the flux linkage at 60° is $150 \times 2.0 \times 10^{-4} = 0.030\ \text{Wb}$.
When the flux through a circuit changes, an emf is induced 感应 in it. If the circuit is complete, the emf drives an induced current 感应电流. Faraday's law 法拉第定律 gives instantaneous emf as the negative derivative of flux linkage. A finite interval gives its average:
Moving a magnet into a coil induces an e.m.f. that drives a current
The minus sign is Lenz's law (see below). For magnitudes use $|\bar\varepsilon|=|\Delta(N\Phi)|/\Delta t$. For constant $N$ this is $N|\Delta\Phi|/\Delta t$. An average equals the instantaneous emf throughout the interval only for a constant rate of linkage change. Do not multiply by $N$ again if the supplied graph already shows linkage.
The flux $\Phi = BA\cos\theta$ can change in three ways, and each gives an emf:
$B$ changes: the field through a still coil gets stronger or weaker (a magnet moves near it, or the current in a nearby coil changes).
$A$ changes: the area of the circuit inside the field grows or shrinks (a rod slides along rails, or a coil moves into or out of a field).
$\theta$ changes: the coil rotates in the field (a generator).
A steady field through a still coil gives no emf, however strong it is. Only change matters.
For a school investigation, connect a coil to a sensitive centre-zero meter. Move the same magnet into and out of the coil, keeping its pole orientation fixed, and record the sign of each deflection. Hold the magnet stationary and record no induced signal. Use approved low-voltage supplies for any powered motor demonstration.
Weakly loaded fall: opposite pulses; the faster exit can give a taller pulse
What the graph shows:
The emf is in opposite directions as the magnet enters and leaves: the flux first increases, then decreases.
In this weakly loaded example the second pulse is taller and narrower because the magnet leaves faster. Significant electromagnetic braking or controlled constant-speed motion can change this comparison.
If initial and final linkage are equal and negligible, the signed total area is zero; the two separate pulse areas then have equal magnitudes.
For a magnet oscillating near a coil, emf depends on speed multiplied by the spatial linkage gradient. Reversing the motion reverses the induced polarity at the same position, but maximum speed alone does not locate every voltage peak.
Worked example
A coil of 200 turns has a flux of $4.0 \times 10^{-4}\ \text{Wb}$ through it. The field is switched off and the flux falls to zero in 0.050 s.
For a straight rod, velocity and uniform field mutually perpendicular, with rod length $L$ along the magnetic-force direction, the end-to-end emf magnitude is:
$$\varepsilon = BvL$$
Two ways to see why:
Force on charges. The free electrons in the rod move with it, so it experiences a magnetic force of magnitude $e vB$ along the rod. Electrons pile up at one end until the electric field stops more moving. An emf exists between the ends even without a closed circuit; its energy transfer in a loaded circuit requires a source maintaining the motion.
Flux cut. In a time $\Delta t$ the rod sweeps out an area $Lv\,\Delta t$, so the flux through the circuit changes by $\Delta\Phi = BLv\,\Delta t$, and $\varepsilon = \Delta\Phi/\Delta t = BvL$.
The circuit area grows as the rod moves, so the flux changes and a current flows
When the rails are joined by a resistor $R$, the current is $I = BvL/R$. In this passive resistive circuit, the current in the rod experiences a force $BIL$against the imposed motion. To keep the rod moving at a steady speed, something must push it with an equal force and do work. Ignoring friction, inductive transients and other energy stores, that work becomes thermal energy in the total circuit resistance: the power is $Fv = BILv = \varepsilon I$.
Worked examples
A rod 0.50 m long moves at 4.0 m s⁻¹ across a 0.30 T field. $\varepsilon = 0.30 \times 4.0 \times 0.50 = 0.60\ \text{V}$. With a 2.0 Ω resistor, $I = 0.30\ \text{A}$ and the opposing force is $0.30 \times 0.30 \times 0.50 = 0.045\ \text{N}$.
An aircraft with a wingspan of 60 m flies at 250 m s⁻¹ where the vertical part of the Earth's field is $5.0 \times 10^{-5}\ \text{T}$. Between the wing tips, $\varepsilon = 5.0 \times 10^{-5} \times 250 \times 60 = 0.75\ \text{V}$. In this ideal open-path model, charge separation gives an end-to-end emf but no sustained circuit current. A closed loop moving rigidly through a uniform field can have zero net loop emf; do not treat the wing segment alone as a complete generator circuit.
19.5
AHL:矩形线圈进入和离开磁场
English
A rectangular coil moving at a steady speed into a region of uniform field has an emf only while the flux through it is changing.
Emf is the negative gradient of flux linkage: constant during ideal entry or exit, zero while fully enclosed
Entering: only the leading side is inside the field, so it acts like the moving rod: $\varepsilon = NBvL$ for a coil of $N$ turns with that side of length $L$. The flux rises steadily.
Fully inside: both sides cut the field. Their emfs cancel round the loop, and the flux is constant, so $\varepsilon = 0$.
Leaving: only the trailing side is in the field. The flux falls, so the emf has the same size in the opposite direction.
The emf–time graph is the gradient of the flux–time graph, multiplied by $-N$.
Worked example
A square coil of 50 turns, side 0.10 m, moves at 2.0 m s⁻¹ through a 0.40 T field region 0.30 m wide.
Check with Faraday's law: $\Delta(N\Phi) = 50 \times 0.40 \times 0.010 = 0.20\ \text{Wb}$, and $0.20/0.050 = 4.0\ \text{V}$.
Fully inside for $(0.30 - 0.10)/2.0 = 0.10\ \text{s}$ with $\varepsilon = 0$; then 4.0 V the other way for 0.050 s.
19.6
AHL:楞次定律
English
Lenz's law 楞次定律: the induced current flows in the direction that opposes the change that produced it.
Aluminium foil floating above an induction hob: the changing field induces eddy currents in the foil, and their field repels the coil's (Lenz's law)A passive closed coil resists the specified approach or withdrawal
Push a north pole towards a coil: the induced current makes the near end of the coil a north pole, which repels the magnet.
Pull the north pole away: the near end becomes a south pole, which attracts the magnet back.
To find the direction of the current, decide which pole the near end must be, then use the right-hand grip rule on the coil.
Why it must be so: energy conservation
Suppose the induced current helped the change instead. Then a magnet nudged towards a coil would be pulled in faster, which would make a larger current, which would pull harder: kinetic energy and electrical energy would appear from nothing. Lenz's law is energy conservation. In the passive examples here, induced forces resist the imposed motion. Mechanical input supplies transferred electrical energy and any changes in kinetic or magnetic energy. Only in a steady resistive model with negligible other losses or stores does input work equal resistor heating. Lenz polarity applies to emf even when an open circuit prevents sustained current; an induced field can support an existing field that is decreasing.
For a finite interval this polarity is represented by $\bar\varepsilon=-\Delta(N\Phi)/\Delta t$.
Examples of Lenz's law
Eddy-current braking. A metal disc or plate moving through a magnetic field has currents (eddy currents 涡流) induced in it. For the changing-flux geometry, the induced effect opposes motion, so the plate slows down and its kinetic energy becomes thermal energy. Some trains and roller coasters brake this way, with no parts touching.
A magnet dropped down a copper pipe falls slowly: currents induced in the pipe walls oppose its motion.
The rod on rails feels a force against its motion (previous section).
A generator is harder to turn when it is supplying a current than when its circuit is open.
A generator 发电机 has a coil turning at a steady rate in a magnetic field. As it turns, the angle $\theta$ changes, so the flux $\Phi = BA\cos\omega t$ keeps changing and an alternating emf is induced.
Emf is greatest where the flux changes fastest, not where it is largest
When the coil plane is perpendicular to the field, flux is at a positive or negative extremum and its instantaneous rate of change is zero, so emf is zero.
When the plane of the coil is parallel to the field, the flux is zero but changing fastest, so the emf is greatest.
The emf graph is the flux graph's gradient (times $-N$): a cosine flux gives a sine emf.
The effect of the rotation frequency
If the coil turns twice as fast:
Twice as fast: double frequency, double peak
the frequency of the alternating emf doubles (twice as many cycles each second);
the peak emf doubles, because the same change of flux happens in half the time.
For a rectangular coil the peak emf is $\varepsilon_0 = NBA\omega$, where $\omega = 2\pi f$. Differentiating $N\Phi=NBA\cos\omega t$ gives this result and shows that the peak is proportional to the frequency. A bigger field, a larger coil area or more turns also increase the peak emf, but they do not change its frequency.
Worked example
A coil of 100 turns and area $0.010\ \text{m}^2$ turns at 50 revolutions per second in a field of 0.20 T. $\omega = 2\pi \times 50 = 314\ \text{rad s}^{-1}$, so $\varepsilon_0 = 100 \times 0.20 \times 0.010 \times 314 = 63\ \text{V}$. At 25 revolutions per second the peak would be 31 V and the frequency 25 Hz.
An emf is induced by a changing field even when nothing moves. A transformer 变压器 uses this: an alternating current in the primary coil makes an alternating flux in an iron core, and that changing flux passes through the secondary coil and induces an alternating emf there.
A substation transformer: changing magnetic flux in coils induces the voltages that power the gridThe changing flux in the core links the two coils
In the ideal fully linked model, each turn has the same changing flux, so induced emf per turn is equal: $V_s/V_p = N_s/N_p$ for an ideal transformer. Use matching quantities, such as rms voltages of the same waveform, and neglect winding resistance and leakage for terminal-voltage equality.
A steady current makes steady flux, so it gives no continuing secondary emf. Alternating or suitably pulsed current provides changing flux. A maintained DC voltage on an ideal zero-resistance primary would demand continuously changing flux, not an ordinary steady operating state; a real DC-connected winding has transients, resistance and possible core saturation. It is not a suitable substitute for an AC supply.
Wireless charging uses coupled coils separated by a gap, with driving/control and receiving circuits; alignment, coupling and losses matter.
Self-induction (qualitative)
A coil's own changing current changes the flux through itself, so it induces an emf in itself. This is self-induction 自感. By Lenz's law, this emf opposes the change in current:
A coil delays the rise of current
when a current is switched on in a coil, the self-induced emf opposes the rise, so the current grows gradually instead of instantly;
when the current is switched off, the self-induced emf tries to keep it flowing. With many turns and an iron core this emf can be large enough to make a spark across the switch.
Self-induction is required only qualitatively.
探索
Turns set the AC voltage ratio
Fewer secondary turns reduce voltage; more secondary turns increase it.
HL. Define magnetic flux, give its unit and state the uniform-field assumption in $\Phi=BA\cos\theta$. A 0.0050 m² coil is in 0.40 T. Find flux when its normal is at 0°, 30° and 90° to the field.
HL. State Faraday's law and Lenz's law, distinguishing an average emf from an instantaneous emf.
HL. In a 500-turn coil, flux reverses from $+3.0\times10^{-4}$ to $-3.0\times10^{-4}$ Wb per turn in 0.020 s. Find average emf magnitude and explain why the flux change is doubled.
HL. A magnet falls through a weakly loaded coil, giving opposite voltage pulses, the second taller and narrower. Explain their signs, conditional height comparison and equal area magnitudes if initial and final linkage are equal.
HL. A 0.25 m rod moves at 6.0 m/s in 0.50 T, with rod, velocity and field mutually perpendicular. Rails close it through total resistance 1.5 Ω. Find emf, current, maintaining force and resistor power; explain the energy source.
HL. A square coil has 20 turns, side 0.050 m and speed 0.50 m/s through a sharp-edged 0.80 T region wider than the coil. Find entry emf and its duration, state the fully enclosed emf, and sketch flux and signed emf through entry and exit using a stated normal.
HL. A north pole is pulled away from a passive closed coil. State its near-face polarity and viewed current direction; explain using Lenz's law and energy conservation. Must an induced field always oppose the original field?
HL. Explain why eddy currents slow a magnet in a copper pipe, but a comparable plastic pipe lacks this strong braking. State one way to reduce eddy-current loops in a metal plate.
HL. A coil rotates uniformly in a fixed uniform field. Give its plane orientation when emf is zero and when emf magnitude is greatest. At fixed coil and field, what happens to emf frequency and peak if rotation frequency halves?
HL. An 80-turn coil of area 0.020 m² rotates at 20 revolutions per second in 0.15 T. Find peak emf.
HL. An ideal transformer has 250 primary turns, 100 secondary turns and 20 V rms input. Find output rms voltage. Explain why a steady primary current gives no continuing secondary emf, while a switching transient can.
HL. Explain the gradual current rise when a circuit containing resistance and a large coil is switched on, and the possibility of a spark when switched off. Identify the energy store supplying a discharge.
HL. Flux-linkage readings are 0 Wb at 0 s, 0.12 Wb at 0.040 s, 0.12 Wb at 0.100 s and 0 Wb at 0.120 s. Assuming linear changes between readings, find signed emf on each interval, and the signed total voltage-time area. The stated positive normal fixes the flux signs.
HL. The rod in question 5 is disconnected from the resistor while its speed is maintained. What happens to its open-circuit emf and sustained current? Explain why an isolated aircraft wing segment can have an end-to-end emf without constituting a complete generator circuit.
Answers.
HL. Signed normal field component times area, for a uniform field over a flat area; $1\ \mathrm{Wb}=1\ \mathrm{T\,m^2}$. Fluxes are 0.0020 Wb, $0.0020\cos30°=0.00173$ Wb and zero.
HL. Instantaneous $\varepsilon=-d(N\Phi)/dt$; average $\bar\varepsilon=-\Delta(N\Phi)/\Delta t$. Lenz polarity opposes the change producing induction. A finite-difference average need not equal the local gradient.
HL.$\Delta\Phi=(-3.0-3.0)\times10^{-4}=-6.0\times10^{-4}$ Wb; $|\bar\varepsilon|=500(6.0\times10^{-4})/0.020=15$ V. Reversal crosses zero rather than merely reaching it.
HL. Linked flux first increases, then decreases, reversing the rate's sign. With weak braking the magnet can leave faster, making a taller, shorter pulse. Equal endpoint linkage gives $\int\varepsilon\,dt=0$, so the two isolated pulse areas cancel; equal heights are unnecessary.
HL.$\varepsilon=BvL=0.75$ V; $I=0.75/1.5=0.50$ A; $F=BIL=0.0625$ N, about 0.063 N. $P=\varepsilon I=I^2R=Fv=0.375$ W, about 0.38 W. The external maintaining force supplies resistor heating in the stated steady ideal model.
HL.$|\varepsilon|=NBvL=0.40$ V during entry for $0.050/0.50=0.10$ s. Fully enclosed emf is zero. Flux rises linearly, stays constant, then falls linearly; for positive inward normal and inward field the entry emf is negative and exit positive. Exit duration and magnitude equal entry at constant speed.
HL. Near face south; conventional current clockwise viewed from the withdrawing north pole. Attraction resists withdrawal; external work supplies the transferred energy. The induced field supports the original field as it decreases, so it need not oppose that field itself.
HL. Changing flux drives conducting loops in copper; their effect opposes the fall and energy is dissipated as heat. Plastic cannot support comparable conduction-current loops. Slots interrupting the paths reduce eddy currents in a metal plate.
HL. Perpendicular coil plane gives positive or negative flux extrema and zero emf. Parallel plane gives zero flux and greatest emf magnitude. Halving frequency halves both emf frequency and peak; linkage amplitude is unchanged.
HL.$\omega=2\pi(20)=125.66$ rad/s; $\varepsilon_0=NBA\omega=80(0.15)(0.020)(125.66)=30.16$ V, about 30 V.
HL.$V_s=20(100/250)=8.0$ V rms. Steady current gives constant flux; its time derivative is zero. Switching changes flux and can induce a transient. Do not confuse fixed current with a maintained voltage on an ideal zero-resistance winding.
HL. Rising current changes self-flux, inducing an emf opposing the rise. At opening, the induced polarity supports the previous current and can create a large voltage across the gap. Stored magnetic energy supplies the subsequent discharge; the coil is not an unlimited source.
HL.$-0.12/0.040=-3.0$ V, zero, then $-(0-0.12)/0.020=+6.0$ V. Areas are $-0.12$, 0 and $+.12$ V s, summing to zero. Linkage already includes turns, so do not multiply by $N$ again.
HL. Ideal open-circuit emf remains 0.75 V after charge separation; sustained circuit current becomes zero. The wing segment can likewise separate end charges. A complete rigid loop in a uniform field may have cancelling segment emfs, and requires a full circuit analysis rather than one isolated segment.
19.10
考试技巧
English
HL. Flux uses the angle to the normal: $\Phi = BA\cos\theta$. If a question gives the angle between the field and the plane of the coil, use $\sin$ instead.
HL. Emf depends on the rate of change of flux, not on the size of the flux. A strong steady field induces nothing.