In this experiment, you will determine the focal length of a converging lens by two methods.
Refer to Fig. 3.1.

Set up the apparatus as shown in Fig. 3.1.
Set the distance $u$ between the illuminated object and the lens to 20.0 cm.
Switch on the lamp.
Place the screen near the lens. Move the screen until a sharp image of the illuminated object is seen on the screen.
Describe a technique for obtaining an image that is as sharp as possible.[1]
Measure $v$, the distance from the lens to the screen as indicated in Fig. 3.1.
$v$ = cm
Measure $h_O$, the height of the illuminated object, indicated in Fig. 3.1.
$h_O$ = cm
Measure $h_I$, the height of the image on the screen.
$h_I$ = cm[2]
Switch off the lamp.
Calculate a value $M$ for the magnification, using the equation $M = \frac{h_I}{h_O}$.
$M$ = [1]
Calculate a value $f_1$ for the focal length of the lens. Use your values from (a)(ii) and (a)(iii) and the equation $f_1 = \frac{v}{(M + 1)}$.
Give an appropriate unit.
$f_1$ = [2]
Describe one difficulty that is experienced when using a ruler to measure the height of the image. Suggest an improvement to the apparatus to overcome this.
You are not required to do an experiment with this improved apparatus.
difficulty
improvement [2]
Adjust the position of the lens so that $u = 40.0$ cm.
Switch on the lamp.
Place the screen near the lens. Move the screen until a sharp image of the illuminated object is seen on the screen.
Measure the distance $v$ between the lens and the screen as indicated in Fig. 3.1.
$v$ = cm[1]
Switch off the lamp.
Calculate a second value $f_2$ for the focal length of the lens. Use your values from (d) and the equation $f_2 = \frac{uv}{(u + v)}$.
$f_2$ = [1]
Suggest which value of focal length, $f_1$ or $f_2$, might be more accurate. Explain your answer.
[1]