Electrical Machines and Power Systems
University Electrical Engineering Topic 9 8:32 English narration · English and 中文 subtitles you can switch
Chapters
Transcript
This course walks the energy chain upward: flux in a magnetic core, torque in a machine, power across a transmission line, and the duty cycle of a switch.
本课程沿着能量链逐步展开:磁芯中的磁通、电机中的转矩、输电线上的功率,以及开关的占空比。
Magnetic circuits and machines come first, then the networks that connect them, then the power electronics that control the energy.
我们先学习磁路和电机,再学习连接它们的电网,最后学习控制能量的电力电子技术。
The checking habit never changes: every power balance must close.
检查的习惯始终不变:每一处功率都必须平衡。
Flux follows an Ohm's law of its own: the magnetomotive force N I drives it, and the reluctance resists it.
磁通遵循自己的欧姆定律:磁动势 N I 驱动磁通,磁阻阻碍磁通。
Two hundred turns at half an amp give 1 milliweber, a flux density of 1 tesla, which must stay below saturation.
200 匝线圈通过半安培电流时产生 1毫韦伯的磁通,磁通密度为 1特斯拉,必须保持在饱和值以下。
A transformer's open-circuit test measures its constant core loss; its short-circuit test measures copper loss, which grows with load squared.
变压器的空载试验测量恒定的铁损;短路试验测量铜损,铜损随负载的平方增大。
Point at the loop on this figure: the coil on the left drives flux around the core, and the reluctance below resists it.
看图中的磁通回路:左侧线圈驱动磁通绕磁芯流动,下方的磁阻阻碍磁通。
Air is about four thousand times weaker than iron, so a gap as thin as a hair can take four fifths of the total reluctance.
空气的导磁能力大约只有铁的四千分之一,因此一条头发丝那么薄的气隙就可能占总磁阻的五分之四。
A transformer simply shares this same flux loop between two windings.
变压器就是让两个绕组共用同一个磁通回路。
Name each branch by its test.
根据对应的试验来辨认每个支路。
The open-circuit test, with no load, fills in the shunt magnetising pair, the core loss.
无负载时的空载试验确定并联励磁支路的两个元件,也就是铁损支路。
The short-circuit test, at rated current, fills in the series pair, the copper loss.
额定电流下的短路试验确定串联支路的两个元件,也就是铜损支路。
With 240 watts of core loss and 300 of copper loss, full-load efficiency is 94.9 per cent, peaking at 0.894 of full load.
铁损为 240瓦、铜损为 300瓦时,满载效率为 94.9%,在满载的 0.894 倍时达到最大。
A DC machine has one constant, k phi.
直流电机有一个常数,k φ。
Back EMF equals k phi times speed, and torque equals k phi times armature current.
反电动势等于 k φ 乘以转速,转矩等于 k φ 乘以电枢电流。
With 210 volts at 157.1 radians per second, k phi is 1.337, so 50 amps gives 66.85 newton metres.
在 210伏和 157.1弧度每秒下,k φ 为 1.337,所以 50安培电流产生 66.85牛·米的转矩。
Check the ledger: torque times speed is 10,500 watts, and so is EMF times current.
核对功率收支:转矩乘以转速是 10,500瓦,电动势乘以电流也是如此。
Same power, two faces.
同一功率,两种表现。
Compare the two curves at the rated point.
比较两条曲线在额定点附近的表现。
The shunt motor's speed stays almost flat as the load changes.
并励电动机的转速在负载变化时几乎保持不变。
The series motor's speed collapses as torque rises, and climbs dangerously as load falls, so never run it unloaded.
串励电动机的转速随转矩增大而急剧下降,并在负载减小时升高到危险程度,因此绝不能空载运行。
At rest there is no back EMF, so a 2 ohm starter protects the 0.2 ohm armature.
静止时没有反电动势,所以用一个 2欧姆的启动电阻来保护 0.2欧姆的电枢。
In an induction machine, the rotating field turns at 120 f over p: 1500 revolutions per minute for a four-pole, 50 hertz machine.
在感应电机中,旋转磁场的转速为 120 f 除以 p:对于一台四极、50赫兹的电机,转速是 1500转每分钟。
The rotor lags behind by the slip.
转子以转差率所表示的程度落后于旋转磁场。
At 1440 revolutions per minute, slip is 0.04 and the rotor current runs at 2 hertz.
当转速为 1440转每分钟时,转差率为 0.04,转子电流频率为 2赫兹。
Rotor copper loss is exactly slip times the air-gap power, here 4 per cent.
转子铜损恰好等于转差率乘以气隙功率,这里是 4%。
Walk the torque-slip curve from starting, up to the breakdown peak of 172 newton metres, and down to the running point.
沿转矩—转差率曲线看,从启动点上升到 172牛·米的最大转矩峰值,再下降到运行点。
Now switch to the curve with doubled rotor resistance.
现在转到转子电阻加倍的曲线。
The peak is just as high, but it moves towards starting, so starting torque rises from 62 to 109 newton metres.
峰值高度不变,但向启动点移动,因此启动转矩从 62 上升到 109牛·米。
Slip also splits the power: 4 per cent copper, 96 per cent shaft.
转差率也决定功率的分配:4%为铜损,96%为轴功率。
A synchronous machine turns at exactly synchronous speed; load changes only its power angle, delta.
同步电机以严格的同步转速旋转;负载只改变它的功角 δ。
Power equals 3 V E over X s, times sine delta.
功率等于 3 V E 除以 X s,再乘以 sin δ。
On an 11 kilovolt system with 5 ohms of reactance and 12 kilovolts of excitation, the maximum is 26.4 megawatts.
在一个 11千伏的系统中,电抗为 5欧姆、励磁电动势为 12千伏时,最大功率为 26.4兆瓦。
At 30 degrees it delivers 13.2, a 100 per cent margin.
在 30度时,它输出 13.2,裕量为 100%。
Excitation sets the reactive power.
励磁决定无功功率。
Read the power-angle curve like a spring shaped as a sine.
把功角特性曲线想象成一条正弦形的弹簧。
Power grows with the angle up to its 26.4 megawatt peak at 90 degrees.
功率随角度增大而上升,在 90度时达到 26.4兆瓦的峰值。
The operating point at 30 degrees delivers 13.2 megawatts, and the shaded area is the margin before the machine pulls out of step.
30度的运行点输出 13.2兆瓦,阴影区域表示电机失步之前的裕量。
Excitation is the second dial, moving reactive power far more than real power.
励磁是第二个调节量,它对无功功率的影响远大于对有功功率的影响。
For a synchronous machine at constant real power, the EMF phasors end on the same horizontal line, where E sin delta is constant.
对于有功功率恒定的同步电机,电动势相量的末端都落在同一条水平线上,此时 E sin δ 为常数。
An over-excited machine, with E1 projecting beyond V, exports reactive power.
过励磁电机的 E1 投影超过 V,向外输出无功功率。
An under-excited one, with E2 falling short, imports it.
欠励磁电机的 E2 投影未达到 V,从外部吸收无功功率。
The per-unit system divides every impedance by a base: on 100 megavolt-amperes at 132 kilovolts, the base is 174.2 ohms, so a 40 ohm line is 0.230 per unit.
标幺制用基准值去除每个阻抗:在 100 兆伏安、132 千伏的基准下,基准阻抗为 174.2 欧姆,因此一条 40 欧姆线路的阻抗为 0.230 标幺值。
Per-unit values pass through transformers unchanged.
标幺值经过变压器时保持不变。
A transformer of 0.10 plus the line gives 0.330 to a fault, so the fault current is 3.03 per unit: 1327 amps at 132 kilovolts.
变压器的 0.10 加上线路阻抗,到故障点的总阻抗为 0.330,所以故障电流为 3.03 标幺值:在 132 千伏下为 1327 安培。
Follow the chain from the generator, through the 0.10 per unit transformer and the 0.230 per unit line, to the fault.
沿着电路从发电机出发,经过 0.10 标幺值的变压器和 0.230 标幺值的线路,到达故障点。
All values are dimensionless, so they simply add: 0.330 per unit.
所有数值都是无量纲的,所以直接相加得到 0.330 标幺值。
The same 3.03 per unit current reads 1327 amps at 132 kilovolts, and about 15,900 amps at 11 kilovolts.
同一个 3.03 标幺值的电流,在 132 千伏下是 1327 安培,在 11 千伏下约为 15,900 安培。
One number serves every voltage level.
一个数值适用于所有电压等级。
The power station delivers 100 megawatts at 25 kilovolts and 4000 amps.
发电站以 25 千伏的电压和 4000 安培的电流输送 100 兆瓦的功率。
A transformer steps the voltage up 16 times, to 400 kilovolts, so the current falls to 250 amps.
变压器将电压升高 16 倍,达到 400 千伏,因此电流降至 250 安培。
In 2 ohms of cable, the loss is 250 squared times 2, 125 kilowatts.
在 2 欧姆的电缆中,损耗是 250 的平方乘以 2,即 125 千瓦。
At 4000 amps it would be 32 megawatts.
如果电流为 4000 安培,损耗将达到 32 兆瓦。
In a two-bus power flow, we know the load and want the voltage.
在双母线潮流计算中,我们已知负载,要求电压。
Iterate: V2 equals 1 minus Z times the conjugate of S over V2.
进行迭代:V2 等于 1 减去 Z 乘以 S 除以 V2 的共轭。
With a line of 0.02 plus j 0.10 and a load of 0.8 plus j 0.4, V2 settles at 0.937 per unit.
线路阻抗为 0.02 加 j 0.10,负载为 0.8 加 j 0.4 时,V2 稳定在 0.937 标幺值。
The reactive term causes two thirds of the drop, so capacitors are the standard fix.
无功项造成了三分之二的电压降,因此电容器是标准的解决办法。
Guess, correct, repeat: watch both cases settle within a few passes.
猜测、修正、重复:观察两种情况都在几次迭代后稳定下来。
As loaded, the receiving bus settles at 0.937 per unit.
在原有负载下,受端母线电压稳定在 0.937 标幺值。
Add 0.3 per unit of shunt capacitors and it settles at 0.970, no slower.
加入 0.3 标幺值的并联电容器后,电压稳定在 0.970,收敛速度并没有变慢。
Voltage magnitude belongs mainly to reactive power, and the angle mainly to real power, which is why these two problems are handled separately.
电压幅值主要与无功功率有关,相角主要与有功功率有关,因此这两个问题要分别处理。
A switching converter is a transformer whose ratio is a duty cycle.
开关变换器就像一个变比由占空比决定的变压器。
A buck converter gives V out equals D times V in, and a boost gives V in over 1 minus D.
降压变换器满足输出电压等于 D 乘以输入电压,升压变换器的输出为输入电压除以 1 减 D。
Stepping 12 volts down to 5 at 2 amps needs D of 0.417, and with 100 microhenries at 100 kilohertz the ripple is 0.29 amps.
将 12 伏特降至 5 伏特、输出 2 安培时,需要的 D 为 0.417;使用 100 微亨的电感,开关频率为 100 千赫兹时,纹波电流为 0.29 安培。
Efficiency here is 94.6 per cent.
此时效率为 94.6%。
The top trace is the switch node, chopping between 12 volts and zero at 100 kilohertz, on for 41.7 per cent of each period.
上面的波形是开关节点电压,以 100 千赫兹的频率在 12 伏特和零之间切换,每个周期有 41.7% 的时间处于导通状态。
The bottom trace is the inductor current, ramping up and down by 0.29 amps around an average of exactly 2 amps.
下面的波形是电感电流,围绕恰好为 2 安培的平均值上下变化,纹波为 0.29 安培。
Half the ripple is far less than the load, so the current never reverses.
纹波的一半远小于负载电流,所以电流始终不会反向。
Now test yourself from memory.
现在凭记忆自测。
With 240 watts of core loss and 300 of copper loss, what is full-load efficiency?
铁损为 240 瓦、铜损为 300 瓦时,满载效率是多少?
A 1500 revolution machine runs at 1440: what are the slip and rotor frequency?
一台同步转速为 1500 转的电机以 1440 转运行:转差率和转子频率是多少?
A boost converter steps 12 volts to 24 at 1.5 amps: what input current flows?
升压变换器将 12 伏特升至 24 伏特,输出电流为 1.5 安培:输入电流是多少?
Pause, answer, then compute.
暂停一下,回答后再计算。
Comments