Gas/liquid chromatography
Introduzido| English | Significado |
|---|---|
| carrier gas/ˈkærɪə ɡæs/ | gás portador |
| retention time/rɪˈtenʃn taɪm/ | tempo de retenção |
| chromatogram/krəʊˈmætəɡræm/ | cromatograma |
| mass spectrometer/mæs spekˈtrɒmɪtə/ | espectrômetro de massas |
Separating a vapour
- Gas/liquid chromatography (GLC) separates a mixture of volatile components.
- The mobile phase is a carrier gas 载气; the stationary phase is a liquid on a solid.
- Each component leaves a peak at its own retention time 保留时间.
Gas/liquid chromatography route
Follow a volatile sample through column separation to a chromatogram.
In gas chromatography, the time a component takes to pass through the column is its ______ time.
Dificuldade 1/5 · Moedas 100 + pequeno bônus na primeira conclusão hoje
Used to identify components.
Gas chromatography separates a mixture of volatile substances.
Dificuldade 1/5 · Moedas 100 + pequeno bônus na primeira conclusão hoje
They travel through the column at different speeds.
How it works
- the stationary phase is a high-boiling-point non-polar liquid on a solid support.
- the mobile phase is an unreactive carrier gas (e.g. nitrogen).
- the retention time is how long a component takes to pass through.
- A component that interacts more with the stationary phase has a longer retention time.

A gas-liquid chromatogram 色谱图 with retention times and peak areas
In GLC, the mobile phase is:
Dificuldade 1/5 · Moedas 100 + pequeno bônus na primeira conclusão hoje
A carrier gas moves the components past the liquid stationary phase.
A component that interacts more strongly with the stationary phase has a:
Dificuldade 1/5 · Moedas 100 + pequeno bônus na primeira conclusão hoje
More interaction slows it down, so it takes longer to pass through (longer retention time).
Reading the chromatogram
- The area of each peak gives the proportion of that component in the mixture.
A chromatogram shows two peaks with areas in the ratio 3 : 1.
- Total = 3 + 1 = 4 parts.
- So the mixture is 75% of the first component and 25% of the second.
(Peak height can mislead — always use the area.)
The area of each peak in a chromatogram gives:
Dificuldade 1/5 · Moedas 100 + pequeno bônus na primeira conclusão hoje
Peak area is proportional to the amount, so it gives the percentage composition.
Identifying the components
- A peak's retention time matches a known standard run in the same conditions → that names the component.
- Coupling GLC to a mass spectrometer 质谱仪 (GC–MS) confirms each component's identity from its mass spectrum.
- GC–MS is the workhorse of forensics, drug testing and airport security.
What changes the retention time
- A more volatile component (lower boiling point) spends more time in the gas, so it comes out sooner.
- A hotter column or a faster gas flow shortens every retention time, so standards must be run under the same conditions.
- When peaks are roughly triangles, estimate each area as $\tfrac{1}{2} \times \text{base} \times \text{height}$.
Peak A: base 2.0 min, height 40 mm. Peak B: base 1.0 min, height 60 mm.
- Area A ≈ ½ × 2.0 × 40 = 40; area B ≈ ½ × 1.0 × 60 = 30.
- A = 40 ÷ 70 = 57% of the mixture, although peak B is taller.
Three peaks have areas 24, 36 and 60 (same detector response). What percentage of the mixture is the second component?
Dificuldade 2/5 · Moedas 140 + pequeno bônus na primeira conclusão hoje
Total area = 24 + 36 + 60 = 120; 36 ÷ 120 × 100 = 30%.
The column temperature is raised. What happens to the retention times?
Dificuldade 1/5 · Moedas 100 + pequeno bônus na primeira conclusão hoje
Hotter components spend more time in the carrier gas, so they pass through the column faster. Compare retention times only under the same conditions.
You've got it
- GLC: mobile phase = carrier gas; stationary phase = a non-polar liquid on a solid
- each component has a retention time; more interaction → longer retention
- the peak area = the proportion of that component (areas 3:1 → 75% : 25%)
- match retention time to a standard to identify; GC–MS confirms it