Skip to content

Practical · Experimental programme

IB Physics SLTopic 20

Video lesson for this topic Open the video page
4:06

Experimental programme

A line passing near every data point is useful, but its gradient can still be uncertain. A graph is evidence for a model within the measurement range.

English narration · English + 中文 subtitles burned in

20.1

Scope and prerequisites

This handout teaches the experimental programme of the course first assessed in 2025: the tools (experimental techniques, technology and mathematics), the inquiry process, and the internal assessment. They are the same for SL and HL students, and they are tested in every paper as well as in the scientific investigation.

Prerequisites: SI units and prefixes, rearranging equations, straight-line graphs ($y = mx + c$), and logarithms. The examples use physics from earlier units, especially the simple pendulum, $T = 2\pi\sqrt{L/g}$.

20.2

Measurement and uncertainty

Faster than light?

In 2011 the OPERA experiment timed neutrinos travelling 730 km from Geneva to Italy and found that they arrived 60 nanoseconds earlier than light would. If true, this would have broken special relativity. The physicists checked their method for months, then published the result and asked others to find the mistake. The timing chain was investigated, including its fibre-optic connection and oscillator; later measurements agreed with the speed of light. CERN reports the timing-system fault. An offset can survive many repeat measurements, so precision alone cannot establish accuracy. Every measurement has an uncertainty, and good physics depends on knowing how large it is and where it comes from.

Neutrinos timed 60 ns early over 730 km, months of checks and publication, a fault found in the timing chain, then later runs agreeing with the speed of light
Precision is not accuracy

Every measurement has an uncertainty

No measurement is exact. The uncertainty 不确定度 quantifies the limitation on a measured result. For $25.4\pm0.1$ cm, the stated interval is 25.3–25.5 cm. Its interpretation depends on how uncertainty was estimated; it is not automatically a guaranteed bound or a stated statistical confidence interval.

Two micrometer readings. Panel a is a zero reading: the thimble edge is at 0 mm and the thimble 0 lines up with the datum line, so it reads 0.00 mm. Panel b is a measurement: the thimble edge has passed 5.5 mm on the main scale and the thimble 28 lines up with the datum line, giving 5.5 + 0.28 = 5.78 mm
Reading a micrometer: add the main scale reading to the thimble reading

How to estimate the uncertainty of a single reading:

  • Analogue scale (ruler, thermometer, meter with a needle): half the smallest division is a common reading estimate when interpolation is reasonable. Include calibration, parallax and reading difficulties where relevant.
  • Digital scale: the last displayed digit is a simple resolution estimate, not proof of accuracy. Manufacturer specifications, calibration and instability may give a larger uncertainty; a display of 85.23 g alone does not establish $\pm0.01$ g accuracy.
  • Measurements by hand: a stopwatch shows 0.01 s, but human reaction time adds about $\pm 0.1$ to $0.2$ s.
  • A length measured with a ruler needs two readings (both ends), so its uncertainty is twice the reading uncertainty if the two endpoint reading uncertainties are treated separately. Aligning an end to a mark does not make the alignment exact; a common additive scale offset can cancel in a difference, while a scale-factor error does not.
A close-up of a micrometer: the sleeve's millimetre scale meets the rotating thimble scale at the datum line
An analogue scale: the smallest division on this micrometer's thimble is 0.01 mm, which sets the reading uncertainty
Quantity Typical instrument Typical uncertainty
length metre rule; vernier caliper; micrometer ±1 mm; ±0.1 mm; ±0.01 mm
mass electronic balance ±0.01 g
time stopwatch; light gate and timer ±0.1–0.2 s (by hand); ±0.001 s
temperature thermometer; temperature sensor ±0.5 °C; ±0.1 °C
current, potential difference digital ammeter, voltmeter resolution estimate; check calibration/specification
angle protractor ±1°
volume measuring cylinder ± half a division
force newton meter; force sensor ± half a division
light or sound intensity light sensor; sound level meter resolution estimate; check calibration/specification

Repeated measurements

For stable repeated measurements, the mean is a useful estimate. Half the range is a simple classroom estimate of repeat scatter, used in the examples here. It is not a universal confidence interval or the standard uncertainty of the mean; include instrument limits and shared calibration errors rather than assuming the range captures everything.

Five timings on a number line from 15.2 to 15.6 s with the mean 15.4 marked and a range of 0.4 s giving plus or minus 0.2 s
Mean and half the range

Example: the time for 10 oscillations of a pendulum is measured five times: 15.2, 15.5, 15.3, 15.6 and 15.4 s.

  • Mean $= 77.0/5 = 15.4$ s. Range $= 15.6 - 15.2 = 0.4$ s, so the uncertainty is $\pm 0.2$ s.
  • Time for 10 oscillations: $15.4 \pm 0.2$ s, so the period is $T = 1.54 \pm 0.02$ s.

For a similar absolute start–stop timing uncertainty, timing ten oscillations and dividing reduces its contribution to the period uncertainty by about ten. There are still start and stop reactions; miscounting oscillations, changing amplitude or a clock scale error are different limitations.

Vocabulary Train
English
uncertainty/ʌnˈsɜːtənti/
20.3

Errors, accuracy and precision

Random and systematic errors

  • Random errors 随机误差 make readings scatter unpredictably about an underlying mean, which may itself be biased. Causes: reaction time, reading a scale, small changes in conditions. Independent repeats reduce the random contribution to uncertainty in the mean; they do not make the scatter of individual readings disappear. Extra graph points help only when the model, sampling and uncertainty treatment are suitable.
  • Systematic errors 系统误差 produce a consistent bias under the measurement conditions; the bias can depend on the measured value. Causes: an instrument that is wrongly calibrated, a zero error 零点误差 (a meter reading 0.02 A with no current), reading a scale from an angle (parallax), heat loss in every trial. Repeating does not reduce them. They are reduced by calibrating, checking zero readings, and improving the method.
Left: random errors scatter points either side of the true line, and the best-fit line passes close to the origin. Right: a systematic zero error shifts every point by the same amount, giving a parallel line with an intercept that is not zero
A systematic error often shows up as an unexpected intercept

A constant additive offset in the dependent variable changes a straight-line intercept without changing its gradient. A multiplicative calibration error changes the gradient; an independent-variable offset changes the inferred intercept too. A zero-compatible intercept therefore does not rule out systematic errors.

Accuracy and precision

  • A measurement is accurate 准确 if it is close to the true value. Systematic errors reduce accuracy.
  • Measurements are precise 精密 if repeated readings are close to each other. Random errors reduce precision.
Three sets of repeated measurements compared with the true value: accurate and precise (close together and centred on the true value), accurate but not precise (widely spread but centred on it), precise but not accurate (close together but all shifted)
Precise is not the same as accurate

Two more words are used when evaluating:

  • Reliability: the method gives consistent results when repeated, by you or by someone else.
  • Validity: the method really measures what the research question asks, with the other variables controlled.
Vocabulary Train
English
random error/ˈrændəm ˈerə/
systematic error/ˌsɪstəˈmætɪk ˈerə/
zero error/ˈzɪərəʊ ˈerə/
accurate/ˈækjʊrət/
precise/prɪˈsaɪs/
20.4

Expressing uncertainties

An uncertainty can be written three ways. For $L = 2.50 \pm 0.05$ m:

Form Calculation Value
absolute uncertainty $\Delta L$ $\pm 0.05$ m
fractional uncertainty $\Delta L/L = 0.05/2.50$ $\pm 0.02$
percentage uncertainty $\Delta L/L \times 100\,\%$ $\pm 2\,\%$

Significant figures

  • Give the uncertainty to one significant figure (two at most), and give the value to the same number of decimal places.
  • $2.3456 \pm 0.0234$ m becomes $2.35 \pm 0.02$ m. $158.2 \pm 7$ s becomes $158 \pm 7$ s.
  • In a table of raw data, every value in a column has the same number of decimal places, matching the instrument.
  • Carry extra digits during calculations, then round the final value to the decimal place of its reported uncertainty. A simple significant-figure rule is a useful check, not a substitute for propagation.
2.3456 plus or minus 0.0234 m: round the uncertainty to one significant figure, 0.02, then the value to the same decimal place, 2.35
Round the uncertainty first

For the following first-order maximum estimates, treat small uncertainties as separate bounds. These are not universal statistical rules. Shared errors can cancel: the same reading $x-x$ is exactly zero. Independent standard uncertainties combine differently. Use positive magnitudes $|y|$ and $|a|$ for signed quantities.

20.5

Propagating uncertainties

When measured values are combined in a calculation, their uncertainties combine too. The data booklet gives the rules:

Bars of percentage uncertainty: for R = V/I the 1.7% of V and 4.0% of I add to 5.7%; for V = a³ three times 0.31% gives 0.94%; for an extension of 25.0 − 12.3 cm the ±0.2 cm is 1.6%
The worked examples as bars: percentages add for a quotient, multiply by the power, and grow when similar values are subtracted.
Calculation Rule
$y = a \pm b$ add the absolute uncertainties: $\Delta y = \Delta a + \Delta b$
$y = \dfrac{ab}{c}$ add the fractional uncertainties: $\dfrac{\Delta y}{y} = \dfrac{\Delta a}{a} + \dfrac{\Delta b}{b} + \dfrac{\Delta c}{c}$
$y = a^n$ multiply the fractional uncertainty by the power: $\dfrac{\Delta y}{y} = \left\lvert n\,\dfrac{\Delta a}{a} \right\rvert$

Worked example: subtraction

A spring is 12.3 ± 0.1 cm long unloaded and 25.0 ± 0.1 cm loaded. Extension $= 12.7 \pm 0.2$ cm. The percentage uncertainty has grown from under 1 % to 1.6 %: subtracting two similar values gives a large percentage uncertainty.

Worked example: a ratio

A resistor has $V = 6.0 \pm 0.1$ V and $I = 0.25 \pm 0.01$ A.

  • $R = V/I = 24\ \Omega$.
  • $\Delta R/R = 0.1/6.0 + 0.01/0.25 = 0.017 + 0.040 = 0.057$.
  • $\Delta R = 0.057 \times 24 = 1.4\ \Omega$, so $R=24.0\pm1.4\ \Omega$ if retaining two significant figures in the uncertainty, or $24\pm1\ \Omega$ with one.

Worked example: a power

A cube has mass $m = 85.2 \pm 0.1$ g and side $a = 3.20 \pm 0.01$ cm.

  • $V = a^3 = 32.8\ \text{cm}^3$, with $\Delta V/V = 3 \times 0.01/3.20 = 0.94\,\%$.
  • $\rho = m/V = 85.2/32.77 = 2.60\ \text{g cm}^{-3}$.
  • $\Delta\rho/\rho = 0.12\,\% + 0.94\,\% = 1.06\,\%$, so $\Delta\rho = 0.03$ and $\rho = 2.60 \pm 0.03\ \text{g cm}^{-3}$.

Notice which measurement matters most: the side length, because it is cubed. To improve the experiment, measure the side more precisely.

Explore

Measurement ranges and the quotient estimate

50 ± 1 mm has a 2% uncertainty. Compare it with a 100 ± 3 mm reading: the summed quotient estimate is 5%, while exact endpoint calculations reveal a slightly asymmetric range.

20.6

Graphs and their uncertainties

Drawing a good graph

  • Put the independent variable on the horizontal axis and the dependent variable on the vertical axis. Label each with the quantity and unit, for example "length L / m".
  • Choose scales so that the points fill most of the grid.
  • Plot uncertainty bars 误差棒 showing the absolute uncertainty of each point. If a bar is too small to draw, say so.
  • Draw a smooth line or curve of best fit with points balanced either side. It does not have to pass through the origin or through every point, and need not pass through every statistical uncertainty bar. For the classroom maximum/minimum-line method, test compatibility with all stated bars; if no line can do so, examine the model, uncertainties and possible outliers rather than forcing a line.
  • A point far from the line may be an outlier 异常值. Check it, and repeat the measurement if you can. Leave it out of the line only with a reason, and say so.
A graph of T squared against L with labelled axes and units, five points with uncertainty bars, a best-fit line and dashed steepest and shallowest lines
What a good graph shows

A sketch graph has labelled axes but no scales. It shows the shape of a relationship, for example "$I$ increases with $V$, more slowly at high $V$".

Gradient and intercept

  • The gradient 斜率 is $\dfrac{\Delta y}{\Delta x}$, found from a large triangle on the best-fit line, not from two data points. Its unit is the $y$ unit divided by the $x$ unit.
  • The intercept 截距 is where the line crosses the vertical axis.
  • The area under a graph can also mean something: under a velocity–time graph it is displacement, under a force–extension graph it is work done.

Uncertainty in the gradient

Pendulum dataset with vertical uncertainty ±0.08 s², negligible horizontal uncertainty and best-fit gradient 4.03 s²/m; limiting compatible gradients are 4.297 and 3.763 s²/m
Data: both limiting lines are checked against every vertical bar, not only the endpoints
  • Draw the steepest and the shallowest straight lines that still pass through all the uncertainty bars. Check every intermediate bar as well: endpoint constructions can miss one. Include horizontal uncertainties as rectangles where significant; the pictured example neglects horizontal uncertainty.
  • Uncertainty in the gradient $= \dfrac{\text{steepest gradient} - \text{shallowest gradient}}{2}$.
  • In a roughly symmetric example, half the intercept span provides an approximate intercept uncertainty. In general, the lines that give extreme gradients need not give the extreme intercepts; determine the intercept range separately if required.

Worked example: finding g with a pendulum

Because $T = 2\pi\sqrt{L/g}$, $T^2 = \dfrac{4\pi^2}{g}L$, so a graph of $T^2$ against $L$ should be a straight line through the origin with gradient $4\pi^2/g$.

  • Best-fit gradient $= 4.03\ \text{s}^2\,\text{m}^{-1}$; steepest 4.30, shallowest 3.76.
  • Uncertainty $= (4.30 - 3.76)/2 = 0.27$, giving an unrounded relative estimate $0.27/4.03=6.7\,\%$. Reporting the gradient to one uncertainty figure gives $4.0\pm0.3\ \text{s}^2\,\text{m}^{-1}$; use unrounded values for the following calculation.
  • $g = 4\pi^2/4.03 = 9.80\ \text{m s}^{-2}$, with the same percentage uncertainty: $\Delta g = 0.067 \times 9.80 = 0.66$. So $g = 9.8 \pm 0.7\ \text{m s}^{-2}$.
  • Here the limiting lines have intercepts about $-0.133$ and $+0.133\ \text{s}^2$, giving a symmetric estimate $c=0.00\pm0.13\ \text{s}^2$. Zero is compatible with the data, supporting proportionality within the tested range; this does not exclude a scale-factor error or prove the model at every length.
Vocabulary Train
English
uncertainty bar/ʌnˈsɜːtənti bɑː/
outlier/ˈaʊtlaɪə/
gradient/ˈɡreɪdɪənt/
intercept/ˌɪntəˈsept/
20.7

Linearising graphs

A straight line is much easier to test than a curve: you can see at once whether the points lie on it, and the gradient and intercept give the constants. To linearise 线性化 a relationship, choose what to plot so that the equation has the form $y = mx + c$.

Left: the period T of a pendulum against length L is a curve. Right: T squared against L is a straight line through the origin
Plotting T² instead of T turns the curve into a straight line
Relationship Plot Gradient Intercept
$T = 2\pi\sqrt{L/g}$ $T^2$ against $L$ $4\pi^2/g$ 0
$s = \tfrac{1}{2}at^2$ $s$ against $t^2$ $a/2$ 0
$F = \dfrac{k}{r^2}$ $F$ against $1/r^2$ $k$ 0
$A=A_0e^{-\lambda t}$ $\ln(A/A_\mathrm{ref})$ against $t$ $-\lambda$ $\ln(A_0/A_\mathrm{ref})$
$y=kx^n$ ($n$ unknown) $\ln(y/y_\mathrm{ref})$ against $\ln(x/x_\mathrm{ref})$ $n$ depends on $k$ and the reference units

The last two use logarithms. Take logarithms of dimensionless ratios to fixed positive reference quantities. For $y=kx^n$, the gradient is $n$, while the intercept is $\ln(kx_\mathrm{ref}^{n}/y_\mathrm{ref})$. All logged values must be positive. The common shorthand “ln A” means the log of its numerical value in stated units; changing units changes the intercept, not the fitted exponent or decay constant. This is how to find an unknown power: for a pendulum, a graph of $\ln T$ against $\ln L$ has gradient 0.5.

A logarithmic scale goes up in equal factors (1, 10, 100, …) rather than equal steps. It is useful when data cover a very large range, such as the luminosities on an HR diagram.

Vocabulary Train
English
linearise/ˈlɪnɪəraɪz/
20.8

Technology in practical work

  • Sensors and data loggers measure quantities such as position, force, temperature, light intensity and current many times a second, without a human start–stop reaction contribution. Sensor response time, sampling rate, timing calibration and triggering can still limit results. Calibrate a sensor first, for example against a known mass or temperature.
  • Light gates time a moving object precisely: the time for a card of known length to pass gives its speed.
  • Video analysis (for example with free software such as Tracker) records motion and gives position against time frame by frame.
  • Spreadsheets process data, calculate uncertainties and plot graphs. A spreadsheet can also give the gradient, but you should still check the steepest and shallowest lines.
  • Simulations and models, such as PhET, generate data and let you test ideas that are hard or dangerous to measure directly.
  • Databases, such as astronomical star catalogues or weather records, give large sets of real data. You must explain how you selected and sampled the data.
20.9

Designing an investigation

Research question and variables

A good research question 研究问题 names the variables and the system: "How does the length of a simple pendulum (0.20–0.80 m) affect its period?"

  • The independent variable 自变量 is the one you change on purpose (the length).
  • The dependent variable 因变量 is the one you measure (the period).
  • The control variables 控制变量 must stay the same so that the test is fair (the mass of the bob, the amplitude, the type of string). State how you keep each one constant, and why it matters.
A simple pendulum labelled with its length L, the independent variable, and a stopwatch for the period T, the dependent variable, timed over ten oscillations; controlled variables: bob mass, small amplitude, type of string
The pendulum investigation: change L, measure T, keep the rest the same.

Planning the measurements

  • Choose enough distinct values and repeats to reveal the predicted trend and estimate uncertainty. Five or more settings is a useful starting plan for many school experiments, not a universal assessment minimum. Justify the spacing and range within safe conditions and model validity.
  • Repeat each measurement (often three to five times) to reduce random error.
  • Try the method first (a pilot) to find problems early.
  • Choose instruments with an uncertainty small enough for the change you want to see.

Controlling variables in physics

Know when and how to:

  • calibrate measuring apparatus, including sensors;
  • keep environmental conditions constant;
  • insulate against heat loss or gain;
  • reduce friction;
  • reduce electrical resistance (short, thick connecting wires, clean contacts);
  • take background radiation into account (measure it and subtract it).

Safety, ethics and the environment

Identify the hazards and how you will reduce them: heavy masses falling, hot liquids, high voltages, lasers (never look along the beam), radioactive sources (teacher-controlled approved sources, handling tools, short exposure time, distance and source-appropriate shielding/storage under the school protocol). Lead is not a universal shielding instruction for every radiation type. Dispose of materials responsibly, and use energy and resources carefully.

Vocabulary Train
English
research question/rɪˈsɜːtʃ ˈkwestʃn/
independent variable/ˌɪndɪˈpendənt ˈveərɪəbl/
dependent variable/dɪˈpendənt ˈveərɪəbl/
control variable/kənˈtrəʊl ˈveərɪəbl/
20.10

Concluding and evaluating

Comparing with an accepted value

  • Percentage error $= \dfrac{\lvert\text{experimental value} - \text{accepted value}\rvert}{\text{accepted value}} \times 100\,\%$.
  • Percentage change $= \dfrac{\text{new value} - \text{old value}}{\text{old value}} \times 100\,\%$.
  • If reference uncertainty is negligible here, a value inside the stated measurement interval is compatible under that uncertainty model. Otherwise include both uncertainties. Compatibility is not proof of correctness; outside the interval, check uncertainty estimates, statistical variation, assumptions and possible systematic errors.

Example: $g = 9.8 \pm 0.7\ \text{m s}^{-2}$ against the accepted 9.81. From the displayed values, the percentage error is $100|9.8-9.81|/9.81\approx0.10\,\%$, smaller than the 7 % uncertainty, and 9.81 is inside the range 9.1–10.5, so the result agrees.

A number line for g in metres per second squared. The measured 9.8 plus or minus 0.7 spans the interval 9.1 to 10.5, and the accepted value 9.81 lies inside it, so the result agrees; the percentage error of about 0.10 percent is far smaller than the 7 percent uncertainty
Agreement means the accepted value lies inside the measured interval

Writing a conclusion

  • Answer the research question directly, using the processed data: "$T^2$ is proportional to $L$ within the uncertainties, because…".
  • Quote values with their uncertainties.
  • Compare with theory or with a published value, and explain any difference.
  • Discuss how large the uncertainties are, and whether they are small enough to support the conclusion.

Evaluating the method

  • Identify the main sources of error, saying whether each is random or systematic, and estimate its effect: does it make the result too large or too small?
  • Discuss weaknesses and assumptions: for example, the small-angle approximation in the pendulum equation, or heat loss that was ignored.
  • Suggest realistic improvements linked to each weakness: "Use a light gate at the bottom of the swing to remove reaction-time error", not "be more careful".
20.11

The internal assessment

The internal assessment (IA) is a scientific investigation that counts for 20 % of the final grade, at both SL and HL.

  • About 10 hours of class time; you choose your own research question.
  • The investigation must analyse quantitative data; hands-on work, fieldwork, database extraction, simulations and spreadsheet modelling are possible approaches. Explain limitations of the chosen evidence.
  • You write a report of at most 3000 words (tables, graphs, equations, calculations and references do not count).
  • Optional collaboration is limited to groups of at most three; each student needs a unique research question and distinct raw data or an appropriate distinct subset of shared data. Every report, including the method description, is individually authored.
Criterion Marks What gets top marks
Research design 6 a focused research question in a specific context, with relevant theory; methodological choices explained; a method detailed enough for someone else to repeat
Data analysis 6 clear and precise recording and processing of data, with uncertainties considered throughout, relevant to the question
Conclusion 6 a conclusion justified by the analysis, related to the research question and compared with accepted science
Evaluation 6 the impact of specific weaknesses and limitations discussed, with realistic improvements
The physics internal assessment as one bar of four criteria, research design, data analysis, conclusion and evaluation, each worth 6 marks for 24 in total, with what earns top marks under each
Four criteria of 6 marks: 20% of the grade in a report of at most 3000 words

Reference data, theory, methods and software where used, and distinguish your own observations from simulated or examples. The IB Physics guide gives the assessment requirements. The collaborative sciences project is a separate interdisciplinary activity, not a group-authored replacement for the individual investigation.

From data to a justified claim

Record raw values, units, instrument limits and qualitative observations before processing; keep rejected values visible with a reason. For a pendulum, measure pivot to bob centre and keep amplitude small. A length measured too short biases the inferred $g$ low in $g=4\pi^2L/T^2$. More stopwatch repeats cannot correct that length definition.

Raw values with units and instrument limits, processing into means and gradients, a claim with its uncertainty, and a bias check such as a length measured short making g low
From data to a claim

For motion video, place a scale in the plane of motion, view square-on and check frame timing: a distant scale can cause a perspective error. A light-gate card gives average speed over its passage, approximating instantaneous speed only when its speed changes little in that time. For sound levels, decibels are logarithmic, so doubling a displayed dB reading does not double intensity.

Use interpolation inside the observed range cautiously; extrapolation beyond it also assumes the model remains valid. A high correlation does not establish causation if another variable changes. Residuals (measured minus predicted values) reveal curvature, drift or changing scatter that a high correlation coefficient can hide. Report which limitations dominate and connect each proposed improvement to its predicted effect.

20.12

Practice

  1. A length is $2.50 \pm 0.05$ m. State its absolute, fractional and percentage uncertainty.

  2. (a) Distinguish between random and systematic errors, and state how each can be reduced. (b) An ammeter reads 0.02 A when no current flows. State the type of error, and its effect on a graph of current against potential difference.

  3. Five times are measured: 2.31, 2.35, 2.28, 2.40 and 2.33 s. Find the mean and its uncertainty. Use half the range as the repeat-scatter estimate.

  4. Write each to an appropriate number of significant figures: (a) $2.3456 \pm 0.0234$ m; (b) $0.004563 \pm 0.00012$ A.

  5. A rectangle is $4.0 \pm 0.1$ cm by $2.5 \pm 0.1$ cm. Find its area with its uncertainty. Use the first-order maximum-uncertainty rule.

  6. The radius of a sphere is $2.00 \pm 0.02$ cm. Find its volume with its uncertainty.

  7. Two temperatures are $25.0 \pm 0.5$ °C and $18.5 \pm 0.5$ °C. Find the temperature rise with its absolute and percentage uncertainty, and comment.

  8. A trolley travels $1.50 \pm 0.01$ m in $0.62 \pm 0.02$ s. Find its average speed with its uncertainty.

  9. A mass of $0.500 \pm 0.005$ kg moves at $3.0 \pm 0.1$ m s⁻¹. Find its kinetic energy with its uncertainty.

  10. State what to plot to give a straight line, and what the gradient represents: (a) $s = \tfrac{1}{2}at^2$; (b) $A = A_0e^{-\lambda t}$; (c) $P = kV^n$ with $k$ and $n$ unknown.

  11. (a) A best-fit gradient is 2.50, the steepest line through the bars has gradient 2.75 and the shallowest 2.20. State the gradient with its uncertainty. (b) A graph of $T^2$ against $L$ has gradient $4.0 \pm 0.3\ \text{s}^2\,\text{m}^{-1}$. Find $g$ with its uncertainty.

  12. A student finds $g = 9.2 \pm 0.3\ \text{m s}^{-2}$. Find the percentage error from 9.81, state whether the result agrees with the accepted value, and suggest a reason.

  13. Write a research question for an investigation into how the length of a wire affects its resistance, and state the independent, dependent and two control variables.

  14. In a pendulum experiment the period was timed for one oscillation using a hand-held stopwatch. Identify the main weakness, and suggest a realistic improvement.

Answers.

  1. $\pm 0.05$ m; $\pm 0.02$; $\pm 2\,\%$.

  2. (a) Random effects scatter readings about an underlying mean, which may be biased. Independent repeats reduce the random uncertainty in that mean. Systematic effects produce a consistent measurement bias; calibrate, correct the cause or improve the model rather than relying on more repeats. (b) A systematic (zero) error. Every reading is 0.02 A too high, so the line is shifted: the intercept changes, but the gradient does not.

  3. Mean $= 11.67/5 = 2.334$ s; range $= 0.12$ s; so $2.33 \pm 0.06$ s.

  4. (a) $2.35\pm0.02$ m. (b) $0.0046\pm0.0001$ A with one uncertainty figure, or $0.00456\pm0.00012$ A with two; the quoted value matches its uncertainty decimal place.

  5. $A = 10.0\ \text{cm}^2$; $\Delta A/A = 0.1/4.0 + 0.1/2.5 = 6.5\,\%$; $A = 10.0 \pm 0.7\ \text{cm}^2$.

  6. $V = \tfrac{4}{3}\pi r^3 = 33.5\ \text{cm}^3$; $\Delta V/V = 3 \times 1\,\% = 3\,\%$; $V = 34 \pm 1\ \text{cm}^3$.

  7. $6.5 \pm 1.0$ °C, which is 15 %. Subtracting two similar values gives a much larger percentage uncertainty than either reading.

  8. $v=1.50/0.62=2.41935\ \text{m s}^{-1}$. The fractional bound is $0.01/1.50+0.02/0.62=0.0389247$, giving $\Delta v=0.0941728\ \text{m s}^{-1}$. Report $2.42\pm0.09\ \text{m s}^{-1}$; do not round the fractions before multiplying.

  9. $E = \tfrac{1}{2}mv^2 = 2.25$ J; $\Delta E/E = 1\,\% + 2 \times 3.3\,\% = 7.7\,\%$; $E = 2.3 \pm 0.2$ J.

  10. (a) $s$ against $t^2$, gradient $a/2$. (b) $\ln(A/A_\mathrm{ref})$ against $t$, gradient $-\lambda$. (c) $\ln(P/P_\mathrm{ref})$ against $\ln(V/V_\mathrm{ref})$, gradient $n$, intercept $\ln(kV_\mathrm{ref}^n/P_\mathrm{ref})$. Reference quantities are fixed and positive.

  11. (a) $(2.75 - 2.20)/2 = 0.275$, so $2.5 \pm 0.3$. (b) $g = 4\pi^2/4.0 = 9.9\ \text{m s}^{-2}$; percentage uncertainty $0.3/4.0 = 7.5\,\%$; $g = 9.9 \pm 0.7\ \text{m s}^{-2}$.

  12. $100|9.2-9.81|/9.81=6.22\,\%$, about 6%. The interval 8.9–9.5 excludes 9.81 if reference uncertainty is negligible. An underestimated pivot-to-centre length would bias $g$ low; underestimated uncertainty or a model problem should also be considered. This one mismatch does not uniquely identify the cause.

  13. For example: "How does the length of a constantan wire (0.10–1.00 m) affect its resistance?" Independent: length. Dependent: resistance (from $V$ and $I$). Control (any two): material, diameter, temperature of the wire (small current, switch off between readings).

  14. Timing a single oscillation by hand gives a large percentage uncertainty from reaction time. Time 10 or 20 oscillations and divide, or use a light gate at the lowest point.

20.13

Exam tips

  • Give uncertainties to one significant figure and the value to the same decimal place.
  • State the uncertainty model; for separate small bounds add fractional contributions in products and absolute contributions in differences.
  • Find gradients from a large triangle on the line, never from two data points, and include the unit.
  • The uncertainty of a gradient is half the difference between the steepest and shallowest lines through all the bars.
  • When evaluating, name the error, say whether it is random or systematic, say how it affected the result, and give a specific improvement.
Was this helpful?

More topics in IB Physics SL

Log in or create account

IGCSE, A-Level & AP