Fig. 10.1 shows the arrangement for transferring electrical energy from a power station to homes and factories.

Explain why the arrangement includes a step-up transformer and a step-down transformer.
[4]
A transformer has 2000 turns on the primary coil and 500 turns on the secondary coil.
The potential difference (p.d.) across the primary coil is 240V a.c.
Calculate the p.d. across the secondary coil.
p.d. across the secondary coil = V[3]