This handout teaches the experimental programme of the course first assessed in 2025: the tools (experimental techniques, technology and mathematics), the inquiry process, and the internal assessment. They are the same for SL and HL students, and they are tested in every paper as well as in the scientific investigation.
Prerequisites: SI units and prefixes, rearranging equations, straight-line graphs ($y = mx + c$), and logarithms. The examples use physics from earlier units, especially the simple pendulum, $T = 2\pi\sqrt{L/g}$.
25.2
测量与不确定性
English
Faster than light?
In 2011 the OPERA experiment timed neutrinos travelling 730 km from Geneva to Italy and found that they arrived 60 nanoseconds earlier than light would. If true, this would have broken special relativity. The physicists checked their method for months, then published the result and asked others to find the mistake. The timing chain was investigated, including its fibre-optic connection and oscillator; later measurements agreed with the speed of light. CERN reports the timing-system fault. An offset can survive many repeat measurements, so precision alone cannot establish accuracy. Every measurement has an uncertainty, and good physics depends on knowing how large it is and where it comes from.
Precision is not accuracy
Every measurement has an uncertainty
No measurement is exact. The uncertainty 不确定度 quantifies the limitation on a measured result. For $25.4\pm0.1$ cm, the stated interval is 25.3–25.5 cm. Its interpretation depends on how uncertainty was estimated; it is not automatically a guaranteed bound or a stated statistical confidence interval.
Reading a micrometer: add the main scale reading to the thimble reading
How to estimate the uncertainty of a single reading:
Analogue scale (ruler, thermometer, meter with a needle): half the smallest division is a common reading estimate when interpolation is reasonable. Include calibration, parallax and reading difficulties where relevant.
Digital scale: the last displayed digit is a simple resolution estimate, not proof of accuracy. Manufacturer specifications, calibration and instability may give a larger uncertainty; a display of 85.23 g alone does not establish $\pm0.01$ g accuracy.
Measurements by hand: a stopwatch shows 0.01 s, but human reaction time adds about $\pm 0.1$ to $0.2$ s.
A length measured with a ruler needs two readings (both ends), so its uncertainty is twice the reading uncertainty if the two endpoint reading uncertainties are treated separately. Aligning an end to a mark does not make the alignment exact; a common additive scale offset can cancel in a difference, while a scale-factor error does not.
An analogue scale: the smallest division on this micrometer's thimble is 0.01 mm, which sets the reading uncertainty
For stable repeated measurements, the mean is a useful estimate. Half the range is a simple classroom estimate of repeat scatter, used in the examples here. It is not a universal confidence interval or the standard uncertainty of the mean; include instrument limits and shared calibration errors rather than assuming the range captures everything.
Mean and half the range
Example: the time for 10 oscillations of a pendulum is measured five times: 15.2, 15.5, 15.3, 15.6 and 15.4 s.
Mean $= 77.0/5 = 15.4$ s. Range $= 15.6 - 15.2 = 0.4$ s, so the uncertainty is $\pm 0.2$ s.
Time for 10 oscillations: $15.4 \pm 0.2$ s, so the period is $T = 1.54 \pm 0.02$ s.
For a similar absolute start–stop timing uncertainty, timing ten oscillations and dividing reduces its contribution to the period uncertainty by about ten. There are still start and stop reactions; miscounting oscillations, changing amplitude or a clock scale error are different limitations.
Random errors 随机误差 make readings scatter unpredictably about an underlying mean, which may itself be biased. Causes: reaction time, reading a scale, small changes in conditions. Independent repeats reduce the random contribution to uncertainty in the mean; they do not make the scatter of individual readings disappear. Extra graph points help only when the model, sampling and uncertainty treatment are suitable.
Systematic errors 系统误差 produce a consistent bias under the measurement conditions; the bias can depend on the measured value. Causes: an instrument that is wrongly calibrated, a zero error 零点误差 (a meter reading 0.02 A with no current), reading a scale from an angle (parallax), heat loss in every trial. Repeating does not reduce them. They are reduced by calibrating, checking zero readings, and improving the method.
A systematic error often shows up as an unexpected intercept
A constant additive offset in the dependent variable changes a straight-line intercept without changing its gradient. A multiplicative calibration error changes the gradient; an independent-variable offset changes the inferred intercept too. A zero-compatible intercept therefore does not rule out systematic errors.
Accuracy and precision
A measurement is accurate 准确 if it is close to the true value. Systematic errors reduce accuracy.
Measurements are precise 精密 if repeated readings are close to each other. Random errors reduce precision.
Precise is not the same as accurate
Two more words are used when evaluating:
Reliability: the method gives consistent results when repeated, by you or by someone else.
Validity: the method really measures what the research question asks, with the other variables controlled.
An uncertainty can be written three ways. For $L = 2.50 \pm 0.05$ m:
Form
Calculation
Value
absolute uncertainty
$\Delta L$
$\pm 0.05$ m
fractional uncertainty
$\Delta L/L = 0.05/2.50$
$\pm 0.02$
percentage uncertainty
$\Delta L/L \times 100\,\%$
$\pm 2\,\%$
Significant figures
Give the uncertainty to one significant figure (two at most), and give the value to the same number of decimal places.
$2.3456 \pm 0.0234$ m becomes $2.35 \pm 0.02$ m. $158.2 \pm 7$ s becomes $158 \pm 7$ s.
In a table of raw data, every value in a column has the same number of decimal places, matching the instrument.
Carry extra digits during calculations, then round the final value to the decimal place of its reported uncertainty. A simple significant-figure rule is a useful check, not a substitute for propagation.
Round the uncertainty first
For the following first-order maximum estimates, treat small uncertainties as separate bounds. These are not universal statistical rules. Shared errors can cancel: the same reading $x-x$ is exactly zero. Independent standard uncertainties combine differently. Use positive magnitudes $|y|$ and $|a|$ for signed quantities.
25.5
不确定度的传播
English
When measured values are combined in a calculation, their uncertainties combine too. The data booklet gives the rules:
The worked examples as bars: percentages add for a quotient, multiply by the power, and grow when similar values are subtracted.
Calculation
Rule
$y = a \pm b$
add the absolute uncertainties: $\Delta y = \Delta a + \Delta b$
multiply the fractional uncertainty by the power: $\dfrac{\Delta y}{y} = \left\lvert n\,\dfrac{\Delta a}{a} \right\rvert$
Worked example: subtraction
A spring is 12.3 ± 0.1 cm long unloaded and 25.0 ± 0.1 cm loaded. Extension $= 12.7 \pm 0.2$ cm. The percentage uncertainty has grown from under 1 % to 1.6 %: subtracting two similar values gives a large percentage uncertainty.
Worked example: a ratio
A resistor has $V = 6.0 \pm 0.1$ V and $I = 0.25 \pm 0.01$ A.
$\Delta R = 0.057 \times 24 = 1.4\ \Omega$, so $R=24.0\pm1.4\ \Omega$ if retaining two significant figures in the uncertainty, or $24\pm1\ \Omega$ with one.
Worked example: a power
A cube has mass $m = 85.2 \pm 0.1$ g and side $a = 3.20 \pm 0.01$ cm.
Put the independent variable on the horizontal axis and the dependent variable on the vertical axis. Label each with the quantity and unit, for example "length L / m".
Choose scales so that the points fill most of the grid.
Plot uncertainty bars 误差棒 showing the absolute uncertainty of each point. If a bar is too small to draw, say so.
Draw a smooth line or curve of best fit with points balanced either side. It does not have to pass through the origin or through every point, and need not pass through every statistical uncertainty bar. For the classroom maximum/minimum-line method, test compatibility with all stated bars; if no line can do so, examine the model, uncertainties and possible outliers rather than forcing a line.
A point far from the line may be an outlier 异常值. Check it, and repeat the measurement if you can. Leave it out of the line only with a reason, and say so.
What a good graph shows
A sketch graph has labelled axes but no scales. It shows the shape of a relationship, for example "$I$ increases with $V$, more slowly at high $V$".
Gradient and intercept
The gradient 斜率 is $\dfrac{\Delta y}{\Delta x}$, found from a large triangle on the best-fit line, not from two data points. Its unit is the $y$ unit divided by the $x$ unit.
The intercept 截距 is where the line crosses the vertical axis.
The area under a graph can also mean something: under a velocity–time graph it is displacement, under a force–extension graph it is work done.
Uncertainty in the gradient
Data: both limiting lines are checked against every vertical bar, not only the endpoints
Draw the steepest and the shallowest straight lines that still pass through all the uncertainty bars. Check every intermediate bar as well: endpoint constructions can miss one. Include horizontal uncertainties as rectangles where significant; the pictured example neglects horizontal uncertainty.
Uncertainty in the gradient $= \dfrac{\text{steepest gradient} - \text{shallowest gradient}}{2}$.
In a roughly symmetric example, half the intercept span provides an approximate intercept uncertainty. In general, the lines that give extreme gradients need not give the extreme intercepts; determine the intercept range separately if required.
Worked example: finding g with a pendulum
Because $T = 2\pi\sqrt{L/g}$, $T^2 = \dfrac{4\pi^2}{g}L$, so a graph of $T^2$ against $L$ should be a straight line through the origin with gradient $4\pi^2/g$.
Uncertainty $= (4.30 - 3.76)/2 = 0.27$, giving an unrounded relative estimate $0.27/4.03=6.7\,\%$. Reporting the gradient to one uncertainty figure gives $4.0\pm0.3\ \text{s}^2\,\text{m}^{-1}$; use unrounded values for the following calculation.
$g = 4\pi^2/4.03 = 9.80\ \text{m s}^{-2}$, with the same percentage uncertainty: $\Delta g = 0.067 \times 9.80 = 0.66$. So $g = 9.8 \pm 0.7\ \text{m s}^{-2}$.
Here the limiting lines have intercepts about $-0.133$ and $+0.133\ \text{s}^2$, giving a symmetric estimate $c=0.00\pm0.13\ \text{s}^2$. Zero is compatible with the data, supporting proportionality within the tested range; this does not exclude a scale-factor error or prove the model at every length.
A straight line is much easier to test than a curve: you can see at once whether the points lie on it, and the gradient and intercept give the constants. To linearise 线性化 a relationship, choose what to plot so that the equation has the form $y = mx + c$.
Plotting T² instead of T turns the curve into a straight line
Relationship
Plot
Gradient
Intercept
$T = 2\pi\sqrt{L/g}$
$T^2$ against $L$
$4\pi^2/g$
0
$s = \tfrac{1}{2}at^2$
$s$ against $t^2$
$a/2$
0
$F = \dfrac{k}{r^2}$
$F$ against $1/r^2$
$k$
0
$A=A_0e^{-\lambda t}$
$\ln(A/A_\mathrm{ref})$ against $t$
$-\lambda$
$\ln(A_0/A_\mathrm{ref})$
$y=kx^n$ ($n$ unknown)
$\ln(y/y_\mathrm{ref})$ against $\ln(x/x_\mathrm{ref})$
$n$
depends on $k$ and the reference units
The last two use logarithms. Take logarithms of dimensionless ratios to fixed positive reference quantities. For $y=kx^n$, the gradient is $n$, while the intercept is $\ln(kx_\mathrm{ref}^{n}/y_\mathrm{ref})$. All logged values must be positive. The common shorthand “ln A” means the log of its numerical value in stated units; changing units changes the intercept, not the fitted exponent or decay constant. This is how to find an unknown power: for a pendulum, a graph of $\ln T$ against $\ln L$ has gradient 0.5.
A logarithmic scale goes up in equal factors (1, 10, 100, …) rather than equal steps. It is useful when data cover a very large range, such as the luminosities on an HR diagram.
Sensors and data loggers measure quantities such as position, force, temperature, light intensity and current many times a second, without a human start–stop reaction contribution. Sensor response time, sampling rate, timing calibration and triggering can still limit results. Calibrate a sensor first, for example against a known mass or temperature.
Light gates time a moving object precisely: the time for a card of known length to pass gives its speed.
Video analysis (for example with free software such as Tracker) records motion and gives position against time frame by frame.
Spreadsheets process data, calculate uncertainties and plot graphs. A spreadsheet can also give the gradient, but you should still check the steepest and shallowest lines.
Simulations and models, such as PhET, generate data and let you test ideas that are hard or dangerous to measure directly.
Databases, such as astronomical star catalogues or weather records, give large sets of real data. You must explain how you selected and sampled the data.
25.9
设计探究活动
English
Research question and variables
A good research question 研究问题 names the variables and the system: "How does the length of a simple pendulum (0.20–0.80 m) affect its period?"
The independent variable 自变量 is the one you change on purpose (the length).
The dependent variable 因变量 is the one you measure (the period).
The control variables 控制变量 must stay the same so that the test is fair (the mass of the bob, the amplitude, the type of string). State how you keep each one constant, and why it matters.
The pendulum investigation: change L, measure T, keep the rest the same.
Planning the measurements
Choose enough distinct values and repeats to reveal the predicted trend and estimate uncertainty. Five or more settings is a useful starting plan for many school experiments, not a universal assessment minimum. Justify the spacing and range within safe conditions and model validity.
Repeat each measurement (often three to five times) to reduce random error.
Try the method first (a pilot) to find problems early.
Choose instruments with an uncertainty small enough for the change you want to see.
take background radiation into account (measure it and subtract it).
Safety, ethics and the environment
Identify the hazards and how you will reduce them: heavy masses falling, hot liquids, high voltages, lasers (never look along the beam), radioactive sources (teacher-controlled approved sources, handling tools, short exposure time, distance and source-appropriate shielding/storage under the school protocol). Lead is not a universal shielding instruction for every radiation type. Dispose of materials responsibly, and use energy and resources carefully.
If reference uncertainty is negligible here, a value inside the stated measurement interval is compatible under that uncertainty model. Otherwise include both uncertainties. Compatibility is not proof of correctness; outside the interval, check uncertainty estimates, statistical variation, assumptions and possible systematic errors.
Example: $g = 9.8 \pm 0.7\ \text{m s}^{-2}$ against the accepted 9.81. From the displayed values, the percentage error is $100|9.8-9.81|/9.81\approx0.10\,\%$, smaller than the 7 % uncertainty, and 9.81 is inside the range 9.1–10.5, so the result agrees.
Agreement means the accepted value lies inside the measured interval
Writing a conclusion
Answer the research question directly, using the processed data: "$T^2$ is proportional to $L$ within the uncertainties, because…".
Quote values with their uncertainties.
Compare with theory or with a published value, and explain any difference.
Discuss how large the uncertainties are, and whether they are small enough to support the conclusion.
Evaluating the method
Identify the main sources of error, saying whether each is random or systematic, and estimate its effect: does it make the result too large or too small?
Discuss weaknesses and assumptions: for example, the small-angle approximation in the pendulum equation, or heat loss that was ignored.
Suggest realistic improvements linked to each weakness: "Use a light gate at the bottom of the swing to remove reaction-time error", not "be more careful".
25.11
内部评估
English
The internal assessment (IA) is a scientific investigation that counts for 20 % of the final grade, at both SL and HL.
About 10 hours of class time; you choose your own research question.
The investigation must analyse quantitative data; hands-on work, fieldwork, database extraction, simulations and spreadsheet modelling are possible approaches. Explain limitations of the chosen evidence.
You write a report of at most 3000 words (tables, graphs, equations, calculations and references do not count).
Optional collaboration is limited to groups of at most three; each student needs a unique research question and distinct raw data or an appropriate distinct subset of shared data. Every report, including the method description, is individually authored.
Criterion
Marks
What gets top marks
Research design
6
a focused research question in a specific context, with relevant theory; methodological choices explained; a method detailed enough for someone else to repeat
Data analysis
6
clear and precise recording and processing of data, with uncertainties considered throughout, relevant to the question
Conclusion
6
a conclusion justified by the analysis, related to the research question and compared with accepted science
Evaluation
6
the impact of specific weaknesses and limitations discussed, with realistic improvements
Four criteria of 6 marks: 20% of the grade in a report of at most 3000 words
Reference data, theory, methods and software where used, and distinguish your own observations from simulated or examples. The IB Physics guide gives the assessment requirements. The collaborative sciences project is a separate interdisciplinary activity, not a group-authored replacement for the individual investigation.
From data to a justified claim
Record raw values, units, instrument limits and qualitative observations before processing; keep rejected values visible with a reason. For a pendulum, measure pivot to bob centre and keep amplitude small. A length measured too short biases the inferred $g$ low in $g=4\pi^2L/T^2$. More stopwatch repeats cannot correct that length definition.
From data to a claim
For motion video, place a scale in the plane of motion, view square-on and check frame timing: a distant scale can cause a perspective error. A light-gate card gives average speed over its passage, approximating instantaneous speed only when its speed changes little in that time. For sound levels, decibels are logarithmic, so doubling a displayed dB reading does not double intensity.
Use interpolation inside the observed range cautiously; extrapolation beyond it also assumes the model remains valid. A high correlation does not establish causation if another variable changes. Residuals (measured minus predicted values) reveal curvature, drift or changing scatter that a high correlation coefficient can hide. Report which limitations dominate and connect each proposed improvement to its predicted effect.
25.12
练习
English
A length is $2.50 \pm 0.05$ m. State its absolute, fractional and percentage uncertainty.
(a) Distinguish between random and systematic errors, and state how each can be reduced. (b) An ammeter reads 0.02 A when no current flows. State the type of error, and its effect on a graph of current against potential difference.
Five times are measured: 2.31, 2.35, 2.28, 2.40 and 2.33 s. Find the mean and its uncertainty. Use half the range as the repeat-scatter estimate.
Write each to an appropriate number of significant figures: (a) $2.3456 \pm 0.0234$ m; (b) $0.004563 \pm 0.00012$ A.
A rectangle is $4.0 \pm 0.1$ cm by $2.5 \pm 0.1$ cm. Find its area with its uncertainty. Use the first-order maximum-uncertainty rule.
The radius of a sphere is $2.00 \pm 0.02$ cm. Find its volume with its uncertainty.
Two temperatures are $25.0 \pm 0.5$ °C and $18.5 \pm 0.5$ °C. Find the temperature rise with its absolute and percentage uncertainty, and comment.
A trolley travels $1.50 \pm 0.01$ m in $0.62 \pm 0.02$ s. Find its average speed with its uncertainty.
A mass of $0.500 \pm 0.005$ kg moves at $3.0 \pm 0.1$ m s⁻¹. Find its kinetic energy with its uncertainty.
State what to plot to give a straight line, and what the gradient represents: (a) $s = \tfrac{1}{2}at^2$; (b) $A = A_0e^{-\lambda t}$; (c) $P = kV^n$ with $k$ and $n$ unknown.
(a) A best-fit gradient is 2.50, the steepest line through the bars has gradient 2.75 and the shallowest 2.20. State the gradient with its uncertainty. (b) A graph of $T^2$ against $L$ has gradient $4.0 \pm 0.3\ \text{s}^2\,\text{m}^{-1}$. Find $g$ with its uncertainty.
A student finds $g = 9.2 \pm 0.3\ \text{m s}^{-2}$. Find the percentage error from 9.81, state whether the result agrees with the accepted value, and suggest a reason.
Write a research question for an investigation into how the length of a wire affects its resistance, and state the independent, dependent and two control variables.
In a pendulum experiment the period was timed for one oscillation using a hand-held stopwatch. Identify the main weakness, and suggest a realistic improvement.
Answers.
$\pm 0.05$ m; $\pm 0.02$; $\pm 2\,\%$.
(a) Random effects scatter readings about an underlying mean, which may be biased. Independent repeats reduce the random uncertainty in that mean. Systematic effects produce a consistent measurement bias; calibrate, correct the cause or improve the model rather than relying on more repeats. (b) A systematic (zero) error. Every reading is 0.02 A too high, so the line is shifted: the intercept changes, but the gradient does not.
Mean $= 11.67/5 = 2.334$ s; range $= 0.12$ s; so $2.33 \pm 0.06$ s.
(a) $2.35\pm0.02$ m. (b) $0.0046\pm0.0001$ A with one uncertainty figure, or $0.00456\pm0.00012$ A with two; the quoted value matches its uncertainty decimal place.
$6.5 \pm 1.0$ °C, which is 15 %. Subtracting two similar values gives a much larger percentage uncertainty than either reading.
$v=1.50/0.62=2.41935\ \text{m s}^{-1}$. The fractional bound is $0.01/1.50+0.02/0.62=0.0389247$, giving $\Delta v=0.0941728\ \text{m s}^{-1}$. Report $2.42\pm0.09\ \text{m s}^{-1}$; do not round the fractions before multiplying.
$100|9.2-9.81|/9.81=6.22\,\%$, about 6%. The interval 8.9–9.5 excludes 9.81 if reference uncertainty is negligible. An underestimated pivot-to-centre length would bias $g$ low; underestimated uncertainty or a model problem should also be considered. This one mismatch does not uniquely identify the cause.
For example: "How does the length of a constantan wire (0.10–1.00 m) affect its resistance?" Independent: length. Dependent: resistance (from $V$ and $I$). Control (any two): material, diameter, temperature of the wire (small current, switch off between readings).
Timing a single oscillation by hand gives a large percentage uncertainty from reaction time. Time 10 or 20 oscillations and divide, or use a light gate at the lowest point.
25.13
考试技巧
English
Give uncertainties to one significant figure and the value to the same decimal place.
State the uncertainty model; for separate small bounds add fractional contributions in products and absolute contributions in differences.
Find gradients from a large triangle on the line, never from two data points, and include the unit.
The uncertainty of a gradient is half the difference between the steepest and shallowest lines through all the bars.
When evaluating, name the error, say whether it is random or systematic, say how it affected the result, and give a specific improvement.