跳到主要内容

反应性 2.2 · 速变?化学变化的速率

IB 化学 SL知识点 16

本主题的视频课程 打开视频页面
3:46

有多快?化学变化的速率

更快的反应完成时间更短,但不一定产生更多产物。速率 ⟦速率⟧和最终产量回答的是不同的问题。

英语旁白 · 英中内嵌字幕

16.1

范围与先修条件

English

This handout teaches Reactivity 2.2, How fast? The rate of chemical change, for the course first assessed in 2025.

Prerequisites: concentration and moles from Structure 1.4, enthalpy changes and energy profiles from Reactivity 1.1, and drawing tangents to curves.

16.2

反应速率的测定

English

Why does food last longer in a fridge?

Cooling slows many reactions involved in food deterioration; storage life depends on the food and conditions, rather than a universal two-day or one-week clock. A firework burns in a second, iron rusts over months. Chemists need to know not only what forms but how fast, and how to make a reaction faster or slower.

What rate means

The rate of reaction 反应速率 is the change in the amount or concentration of a reactant or product per unit time.

$$\text{rate} = \frac{\Delta[\text{product}]}{\Delta t} \quad \text{or} \quad -\frac{\Delta[\text{reactant}]}{\Delta t}$$

The unit is usually mol dm⁻³ s⁻¹. If you follow something else, such as a gas volume, the unit follows it: cm³ s⁻¹ or g s⁻¹.

Ways to follow a reaction

What changes Method Example
gas is given off collect the gas in a gas syringe; read the volume every 10 s $\text{CaCO}_3$ + HCl
gas escapes stand the flask on a balance; read the mass loss $\text{CaCO}_3$ + HCl
colour colorimeter: measure how much light passes through bromine reacting with methanoic acid
ions form or are used conductivity or pH meter ester hydrolysis
a precipitate forms time until a cross under the flask disappears sodium thiosulfate + HCl
A glass gas syringe
A gas syringe measures the volume of gas made over time, which gives the rate of reaction

Reading a rate from a graph

Volume of CO₂ against time: the curve is steepest at the start and levels off; a tangent at t = 0 gives an initial rate of 1.2 cm³ s⁻¹ and a tangent at 50 s gives 0.44 cm³ s⁻¹
Gas-collection curve: the tangent gradient estimates the instantaneous volume-production rate.
  • The rate at any time is the gradient of the curve at that time. Draw a tangent 切线 and find its gradient.
  • In this consumption experiment, the curve is steepest at the start. This is not universal: induction periods or autocatalysis can give a later maximum. The initial rate 初始速率 is the gradient of the tangent at $t = 0$.
  • The rate falls as reactants are used up. A flat measured trace means no detectable net change in that observable. Check for completion, dynamic equilibrium, leaks or a sensor limitation before claiming all reaction has stopped.

Choose a slope and specify the species

For a 20–60 s interval, a gas-volume rise from 10.0 to 34.0 cm³ gives mean rate $(34.0-10.0)/(60-20)=0.600$ cm³/s. A tangent through chosen points (30 s, 22 cm³) and (70 s, 46 cm³) also has gradient 0.600 cm³/s, but those must be points on the drawn tangent, not merely two widely separated points on the curve. A tangent estimates an instantaneous rate; a secant averages an interval. A decreasing mass or reactant trace has a negative slope, so define a positive disappearance rate with a minus sign.

A curve of volume of carbon dioxide against time levelling off at 80 cm³, with a tangent drawn at 40 seconds; a triangle under the tangent rises 66 cm³ over 90 s, giving a gradient of 0.73 cm³ per second
The rate at one instant is the gradient of the tangent to the curve at that time

For 2A → B at fixed volume, A disappears twice as quickly as B forms. If $-\Delta[\mathrm A]/\Delta t=0.0060$ mol/dm³/s, B forms at 0.0030 mol/dm³/s. A normalized reaction rate divides each species rate by its coefficient. State which rate the data and rate constant use rather than switching conventions mid-calculation.

Select a defensible experimental signal

A gas syringe needs gas-tight connections and a consistent start; delayed fitting can lose the early, fastest gas production. A mass-loss experiment needs escaping gas and must account for evaporation or spray. For comparisons, control temperature, reagent amount and concentration, gas pressure and the solid's exposed surface as appropriate. Change only the intended factor and repeat to estimate variability.

Four cards for following a rate: gas syringe, mass loss, colorimeter and pH or conductivity, each with its main caveat
Four ways to follow a rate, and what each needs

A colorimeter can follow concentration through absorbance only with an appropriate calibration, wavelength, path length and working range. Conductivity reflects contributions from all mobile ions; pH is logarithmic, so a pH–time slope is not directly a concentration–time slope. A disappearing-cross time gives an approximate relative-rate proxy $1/t$ only when the same observable threshold corresponds to the same amount of change, with comparable path length and observation conditions. It is not automatically an instantaneous rate.

探索

平均速率与瞬时速率

20至60 s内气体体积从10增至34 cm³,平均速率为0.60 cm³/s。比较割线与切线,再改变模型速率而保持最终气体体积不变。

词汇 训练
English 中文 拼音
rate of reaction/reɪt ɒv rɪˈækʃn/ 反应速率 fǎn yìng sù lǜ
tangent/ˈtændʒənt/ 切线 qiē xiàn
initial rate/ɪˈnɪʃl reɪt/ 初始速率 chū shǐ sù lǜ
16.3

碰撞理论

English

Three conditions for a reaction

In the school collision theory 碰撞理论 model for collision-activated reactions, only some encounters lead to products. A successful collision needs:

  1. A collision: the particles must meet.
  2. Enough energy: the collision energy must be at least the activation energy 活化能, $E_a$, the minimum energy needed for a reaction.
  3. The right orientation: the reacting parts of the particles must meet.

The rate depends on how many successful collisions happen each second.

词汇 训练
English 中文 拼音
collision theory/kəˈlɪʒn ˈθɪəri/ 碰撞理论 pèng zhuàng lǐ lùn
activation energy/ˌæktɪˈveɪʃn ˈenədʒi/ 活化能 huó huà néng
16.4

影响反应速率的因素

English

The Maxwell–Boltzmann distribution

The particles in a gas or solution do not all have the same energy. The Maxwell–Boltzmann distribution 麦克斯韦-玻尔兹曼分布 shows how many particles have each energy.

Two Maxwell–Boltzmann curves. (a) At a higher temperature the curve is lower and broader, and much more area lies beyond Ea. (b) A catalyst moves Ea to the left, so more area lies beyond it at the same temperature
The shaded areas are the particles with at least enough energy to react
  • The ideal energy-distribution density starts at zero at the origin. The vertical axis represents numbers per energy interval, not the energy of a single particle.
  • The ideal curve has an unbounded tail that approaches zero as energy increases. A finite drawn window does not show the entire distribution.
  • The area under the curve is the total number of particles. At a higher temperature the area stays the same, so the peak moves right and falls.
  • The shaded tail represents particles above the model energy threshold; sufficient energy is necessary, but appropriate orientation and pathway still matter.

Concentration, pressure and surface area

Change Effect on collisions Effect on rate
higher reactant concentration at fixed temperature more frequent relevant encounters in the simple model often faster; infer dependence from evidence
compression raising reactant partial pressure at fixed temperature more reactant particles per volume often faster
smaller pieces of a solid (larger surface area 表面积) more particles exposed, so more frequent collisions faster
One cube with surface 24 units beside the same mass cut into 8 small cubes with surface 48 units: more particles exposed, more frequent collisions
Cutting a solid doubles its exposed surface here

At fixed temperature and with the same pathway, these changes do not themselves raise the thermal-energy distribution or lower its threshold. Increasing pressure by adding an inert gas at constant volume does not increase the ideal reactant partial pressures. Concentration, surface saturation and complex mechanisms can give behaviours beyond the simplest collision-frequency explanation.

Temperature

A 10 K rise sometimes gives a roughly twofold increase near room temperature, but this is an empirical approximation, not a universal law. Two effects add together:

  1. Mean translational kinetic energy is proportional to absolute temperature in kelvin; particles move faster, so collisions are a little more frequent. For 20 to 40 degrees Celsius, the mean-energy factor is 313.15/293.15 ≈ 1.068, not two.
  2. Much more important: more particles have energy at least $E_a$ (panel (a) above), so a much larger fraction of collisions succeeds.

Catalysts

A catalyst 催化剂 increases the rate through participation in a pathway and is regenerated overall. A catalyst can nevertheless be lost, poisoned or deactivated in practice. It gives an alternative reaction pathway 替代反应途径 with a lower activation energy.

A cylindrical catalytic converter block with a fine honeycomb surface — a real heterogeneous catalyst
A car's catalytic converter is a heterogeneous catalyst; its honeycomb gives a huge surface area
Exothermic and endothermic profiles: the catalysed path has a lower peak, while each example keeps its reactant and product levels and ΔH
A catalyst lowers $E_a$ but does not change $\Delta H$
  • With a lower $E_a$, more particles have enough energy (panel (b) above), so more collisions succeed.
  • A catalyst does not change $\Delta H$, and it does not change the position of an equilibrium.
  • Examples: iron in the Haber process, $\text{MnO}_2$ for the decomposition of hydrogen peroxide, enzymes in living cells.

Read either an exothermic or an endothermic profile

The two-panel figure includes energy levels in kJ per stated reaction amount. For the endothermic example, reactants are at 20, products at 50 and the uncatalysed peak at 100. Thus $\Delta H=+30$, forward barrier $100-20=80$ and reverse barrier $100-50=50$. A catalysed peak at 80 gives barriers 60 and 30, while the endpoints and $\Delta H$ remain unchanged.

Exothermic reactions end lower than the reactants; endothermic end higher
Exothermic reactions end lower than the reactants; endothermic end higher

At the same temperature a catalyst does not heat the sample or change its Maxwell–Boltzmann distribution: it provides another, lower-threshold pathway. It accelerates approach to the same equilibrium composition in a closed system at fixed conditions. In a simple complete reaction with the same limiting amount and no competing pathways, powdering a solid or adding a catalyst can change the time to a plateau without changing that final amount. Different side reactions, deactivation, leaks or collection conditions can invalidate that comparison.

词汇 训练
English 中文 拼音
Maxwell–Boltzmann distribution/ˈmækswel ˈbɒltsmən ˌdɪstrɪˈbjuːʃn/ 麦克斯韦-玻尔兹曼分布 mài kè sī wéi - bō ěr zī màn fēn bù
surface area/ˈsɜːfɪs ˈeərɪə/ 表面积 biǎo miàn jī
catalyst/ˈkætəlɪst/ 催化剂 cuī huà jì
alternative reaction pathway/ɔːlˈtɜːnətɪv rɪˈækʃn ˈpæθweɪ/ 替代反应途径 tì dài fǎn yìng tú jìng
16.5

练习

English
  1. In an experiment, 0.050 mol dm⁻³ of a reactant is used up in 25 s. Calculate the mean rate in mol dm⁻³ s⁻¹.
  2. Describe how to follow the rate of the reaction between magnesium ribbon and hydrochloric acid.
  3. State the three conditions for a successful collision.
  4. Use collision theory to explain why powdered calcium carbonate reacts faster with acid than the same mass of lumps.
  5. Sketch Maxwell–Boltzmann curves at two temperatures and use them to explain why a small rise in temperature gives a large rise in rate.
  6. Explain how a catalyst increases the rate, with reference to an energy profile and a Maxwell–Boltzmann curve.
  7. From the gas–time graph in this handout, explain why the rate at 50 s is lower than the initial rate.
  8. For 2A → B, A concentration falls by 0.030 mol/dm³ in 5.0 s at fixed volume. Find positive A disappearance rate, B formation rate and the coefficient-normalized reaction rate.
  9. A gas trace rises from 10.0 to 34.0 cm³ between 20 and 60 s. Find its mean rate. A tangent through (30 s, 22 cm³) and (70 s, 46 cm³) estimates an instantaneous rate: calculate it and explain what must be checked about the chosen points.
  10. Explain why adding inert gas at fixed temperature and volume need not increase reaction rate. Two disappearing-cross times are 40 s and 25 s under comparable fixed-threshold conditions: find the relative 1/t rate factor and give a limitation of the comparison.
  11. For the endothermic profile with reactants 20, products 50 and peak 100 kJ per reaction amount, find ΔH and both activation barriers. Repeat for a catalysed peak at 80. Explain what happens to the thermal-energy distribution at the same temperature.

Answers.

  1. $0.050 / 25 = 2.0 \times 10^{-3}$ mol dm⁻³ s⁻¹.
  2. Collect the hydrogen in a gas syringe and read the volume every 10 s (or measure the mass loss on a balance); keep the temperature, acid concentration and volume the same.
  3. The particles collide, with energy at least equal to $E_a$, and with the correct orientation.
  4. Powder has a larger surface area, so more particles are exposed and collisions with acid particles are more frequent.
  5. At the higher temperature the curve is lower and broader with the same area; the area beyond $E_a$ is much larger, so a much larger fraction of collisions has enough energy.
  6. It gives an alternative pathway with a lower $E_a$ (a lower peak on the profile, the same $\Delta H$). On the Maxwell–Boltzmann curve the lower $E_a$ line has more particles beyond it, so more collisions succeed.
  7. Reactants have been used up, so their concentration is lower and collisions are less frequent; the tangent is less steep.
  8. A disappearance: $0.030/5.0=0.0060$ mol/dm³/s. Divide by two for B formation and the normalized reaction rate: each is 0.0030 mol/dm³/s.
  9. Mean: $(34.0-10.0)/(60-20)=0.600$ cm³/s. Tangent: $(46-22)/(70-30)=0.600$ cm³/s. The two latter points must lie on the tangent, not simply on the curve. Equality here is a supplied coincidence, not a general equivalence of mean and instantaneous rates.
  10. At constant volume and temperature, ideal reactant partial pressures remain unchanged when inert gas is added. Relative proxy factor $(1/25)/(1/40)=1.6$. The same opacity threshold, optical path and comparable observation conditions are needed; 1/t is not automatically an instantaneous rate.
  11. ΔH = 50−20 = +30 kJ. Uncatalysed barriers: forward 100−20 = 80 and reverse 100−50 = 50 kJ. Catalysed barriers: 80−20 = 60 and 80−50 = 30 kJ. The distribution at fixed temperature stays the same; the alternative pathway has a lower threshold.
16.6

考试技巧

English
  • Rate is measured from the gradient of a tangent; draw the tangent long and read two far-apart points.
  • At fixed temperature, reactant concentration and exposed surface can change encounter frequency. Heating changes the energy distribution; a catalyst changes the pathway threshold.
  • Sketch the ideal Maxwell–Boltzmann density from the origin with a tail approaching zero; keep total area constant for the same particle count.
  • A catalyst does not change $\Delta H$ or the equilibrium position.
这有帮助吗?

更多 IB 化学 SL 知识点

登录或创建账户

IGCSE, A-Level & AP