Experimental programme
IB Chemistry HL Topic 23 18:55 English narration · English and 中文 subtitles you can switch
Chapters
Transcript
When does a graph count as evidence?
什么时候图像可以作为证据?
A straight line can still be biased.
一条直线仍然可能存在偏差。
An investigation needs a measurable question, appropriate methods, honest raw data, and a conclusion that respects the uncertainty.
一项探究需要可测量的问题、恰当的方法、真实的原始数据,以及考虑了不确定度的结论。
This unit connects laboratory techniques, conservative uncertainty propagation, gradients, and model testing; the numerical examples are invented.
本单元联系实验技术、保守的不确定度传播、斜率和模型检验;数值示例均为虚构。
Use these methods throughout supervised practical work, and justify each model you use.
在有指导的实验中始终运用这些方法,并说明所用各个模型的合理性。
Turn a broad topic into a measurable question.
把宽泛的主题转化为可测量的问题。
For example: how does the initial temperature affect the time for a specified magnesium strip to produce 20 cubic centimetres of hydrogen in hydrochloric acid of fixed concentration?
例如:初始温度如何影响指定镁条在固定浓度的盐酸中产生 20 立方厘米 氢气所需的时间?
The independent variable is the initial temperature; the dependent variable is the time to reach that gas volume.
自变量是初始温度;因变量是达到该气体体积所需的时间。
For a fixed collected volume, 1 over t can compare average rates, but it is not automatically an initial rate.
对于固定的收集体积,1 除以 t 可以用来比较平均速率,但它不一定是初始速率。
A list of constants needs reasons.
列出控制变量还需要说明原因。
Control the acid's concentration and volume, and the magnesium's mass and exposed area, because they can alter the reacting amount or the rate.
控制酸的浓度和体积,以及镁的质量和暴露面积,因为它们可能改变反应物的量或反应速率。
Choose a measurable, safe range, and use a pilot to detect a reaction too fast to time, or a gas leak.
选择可测量且安全的范围,并通过预实验发现反应快到无法计时或气体泄漏等问题。
Repeat each condition to judge the scatter, and randomize the order of conditions where useful, to reduce drift.
重复每个条件下的实验以判断数据的离散程度,并在适当时随机安排各条件的实验顺序,以减少随时间产生的漂移。
One condition with many repeats does not establish a trend.
只对一个条件进行多次重复不能确定趋势。
A risk assessment follows the actual method: hazard, exposure, then control.
风险评估要依据实际方法:先考虑危险源,再考虑暴露,最后考虑控制措施。
Acid splash risks eye and skin exposure, so use suitable eye protection and controlled handling.
酸液飞溅可能使眼睛和皮肤接触酸,因此要佩戴合适的护目装备并小心操作。
A flammable solvent risks ignition, so use approved heating, and remove flames.
易燃溶剂有点燃的风险,因此要使用经批准的加热方式,并移除明火。
Follow the apparatus limits and disposal instructions.
遵守仪器使用限制和废弃物处置说明。
And plan waste minimization, and environmental and ethical issues, before collecting data.
采集数据前,还要规划如何减少废弃物,并考虑环境和伦理问题。
Choose volume equipment by its purpose.
根据用途选择量取体积的仪器。
A volumetric pipette delivers one specified volume.
容量移液管移取一个指定体积。
A burette delivers a variable volume: the final reading minus the initial.
滴定管可放出不同体积的液体:体积等于最终读数减去初始读数。
A volumetric flask contains a specified total volume at its mark.
容量瓶在刻度线处容纳指定的总体积。
And a beaker gives only an approximate volume, usually unsuitable for a precise concentration.
烧杯只能给出大致体积,通常不适合配制精确浓度的溶液。
Instrument choice is more than resolution.
选择仪器不只看分辨率。
Tare a stable balance, keep vessels dry, and record the displayed precision.
将稳定的天平去皮,保持容器干燥,并按显示精度记录。
Define the start and finish events for timing, and avoid parallax on scales.
明确计时的起点和终点,并避免读取刻度时产生视差。
Use temperature probes consistently and let them stabilize: even a fast sensor can lag, or have a calibration offset.
一致地使用温度探头,并让读数稳定:即使反应快的传感器也可能有滞后或校准偏移。
Calibrate a pH probe with suitable buffers.
用合适的缓冲溶液校准 pH 探头。
And measure current with an ammeter in series, and potential difference with a voltmeter in parallel.
测量电流时将电流表串联,测量电势差时将电压表并联。
Random error is unpredictable scatter: repeats help estimate it.
随机误差表现为不可预测的散布:重复测量有助于估计它。
Systematic error is a directional bias, including a calibration offset.
系统误差是有方向性的偏差,包括校准偏移。
Precision is the spread, or resolution, of measurements.
精密度指测量值的离散程度或测量的分辨率。
And accuracy is agreement with a suitable reference, under matching conditions.
准确度指在相同条件下与合适参考值的符合程度。
Precision does not establish accuracy.
精密度高不能证明准确度高。
Read the burette at eye level, at the bottom of the meniscus, both before and after.
在滴定前后都要使视线与液面齐平,读取滴定管弯月面的底部。
Burette values increase downwards, and the delivered volume is a difference, not the final reading alone.
滴定管的读数向下增大,放出的体积是两次读数之差,而不是单独的最终读数。
One titre has two reading uncertainties.
一次滴定体积涉及两次读数的不确定度。
In invented readings, the initial is 2.35 plus or minus 0.05 cubic centimetres, and the final 24.85 plus or minus 0.05.
在一组虚构读数中,初始读数为 2.35 正负 0.05 立方厘米,最终读数为 24.85 正负 0.05。
The titre is 24.85 minus 2.35: 22.50 cubic centimetres.
滴定体积等于 24.85 减去 2.35,即 22.50 立方厘米。
Conservatively, add the uncertainties: 0.10.
采用保守估计,将不确定度相加,得到 0.10。
So report 22.50 plus or minus 0.10 cubic centimetres.
因此报告为 22.50 正负 0.10 立方厘米。
Use apparatus specifications and the stated method; do not assume this uncertainty for every burette.
要依据仪器规格和所述方法,不要假设所有滴定管的不确定度都是这个值。
Accurate measurements are centred on the true value; precise measurements are close together.
准确的测量值以真值为中心;精密的测量值彼此接近。
A set can be accurate but not precise, widely spread around the true value, or precise but not accurate, tightly grouped but off-centre, which points to a systematic error.
一组数据可以准确但不精密,即广泛分布在真值周围;也可以精密但不准确,即数据集中却偏离真值,这表明可能存在系统误差。
To prepare a standard solution, use n equals c V, and m equals n M.
配制标准溶液时,使用 n 等于 c V,以及 m 等于 n M。
Dissolve the solid, transfer it quantitatively, rinsing into the volumetric flask, make up to the mark, and mix.
溶解固体,定量转移,洗涤并将洗液转入容量瓶,定容至刻度线,然后混匀。
Purity, hydration and water absorption matter: a precise mass alone does not guarantee an accurate concentration.
纯度、水合情况和吸水都会产生影响:仅有精确的质量不能保证浓度准确。
A dilution conserves the solute amount: c 1 V 1 equals c 2 V 2.
稀释时溶质的量守恒:c 1 V 1 等于 c 2 V 2。
Dilute an aliquot to the final flask volume, not by adding that entire volume of solvent.
将移取的一份溶液稀释至容量瓶的最终体积,而不是加入这个总体积的溶剂。
In a titration, rinse the burette with the titrant, and the pipette with its solution.
滴定时,用滴定液润洗滴定管,用待移取的溶液润洗移液管。
Use a clean conical flask, normally rinsed with deionized water.
使用洁净的锥形瓶,通常用去离子水洗净。
Swirl, and approach the endpoint dropwise.
摇动锥形瓶,接近终点时逐滴加入滴定液。
The equivalence point is stoichiometric; the endpoint is an observation.
等当点由化学计量关系决定;终点则是观察到的现象。
So choose an indicator that changes in the appropriate steep region; some redox titrations are self-indicating.
因此要选择在合适的陡变区间变色的指示剂;有些氧化还原滴定自身可以指示终点。
Use a balanced equation, keep a rough titre separate, and state your rule for choosing concordant careful trials.
使用配平的方程式,将粗滴定结果单独记录,并说明选择相互接近的精细滴定结果的规则。
Filtration retains an insoluble solid, while a dissolved salt passes through.
过滤会截留不溶性固体,而溶解的盐会通过滤纸。
Recrystallization uses a suitable difference in hot and cold solubility; wash the crystals with a little cold solvent.
重结晶利用物质在热溶剂和冷溶剂中适当的溶解度差异;用少量冷溶剂洗涤晶体。
Heating to constant mass repeats a suitable heat, cool and weigh cycle; cool before weighing.
加热至恒重需要重复适当的加热、冷却和称量循环;称量前要冷却。
And a separating funnel separates suitable immiscible liquid layers.
分液漏斗可用于分离适合的互不相溶的液层。
Distillation collects a condensed volatile component, using differences in volatility.
蒸馏利用挥发性的差异,收集冷凝后的挥发性组分。
Reflux returns the condensate during a prolonged reaction; never seal ordinary atmospheric apparatus.
回流在长时间反应中使冷凝液返回;绝不能密封普通的常压装置。
Chromatography compares migration under specified conditions, but a matching R f alone does not prove identity.
色谱法比较指定条件下的迁移情况,但仅凭相同的 R f 不能证明物质的身份。
And a melting range supports a purity assessment, but is not a complete structural identification.
熔程可以辅助评估纯度,但不能完整地确定结构。
Connect the observable to the chemistry.
将可观察的现象与化学联系起来。
Calorimetry uses the heated mass and the temperature change; account for heat exchange, and the apparatus's heat capacity, where relevant.
量热法使用受热物质的质量和温度变化;必要时要考虑热交换和仪器的热容。
For cells, control the electrolyte, the electrode surface, and the temperature; a high-resistance voltmeter reduces the current drawn in a potential measurement.
对于电池,要控制电解质、电极表面和温度;高电阻电压表可减小测量电势差时流过的电流。
Colorimetry needs a suitable wavelength, a blank, consistent cuvettes, and a justified calibration range.
比色法需要合适的波长、空白样品、保持一致的比色皿和有依据的校准范围。
And physical or digital models represent connectivity and geometry, under assumptions.
实体模型或数字模型则在一定假设下表示原子连接关系和几何结构。
In thin-layer chromatography, spots are placed on a baseline, and the solvent rises up the plate.
在薄层色谱中,样品点在基线上,溶剂沿薄层板上升。
Measure the distance the spot moved and the distance the solvent front moved, both from the baseline.
从基线分别测量斑点移动的距离和溶剂前沿移动的距离。
The Rf value is the spot distance over the solvent distance, and comparison with a known substance under the same conditions can support an identification, but does not prove it.
Rf 值是斑点移动距离除以溶剂移动距离,在相同条件下与已知物质比较可以为鉴定提供依据,但不能证明其身份。
A colorimetry calibration line is drawn through a blank and four standards.
比色法校准直线通过空白样品和4 个标准样品绘制。
An unknown read inside that range gives a reliable concentration.
未知样品的读数落在该范围内时,可以得到可靠的浓度。
Beyond the highest standard, the response is not established by the calibration, so extrapolated concentrations may be unreliable.
超过最高标准样品后,校准并未确定响应,因此外推得到的浓度可能不可靠。
Preserve the raw record before processing.
处理数据前先保存原始记录。
Record the original readings, units, apparatus uncertainties, and qualitative changes, with consistent decimal places for the same instrument.
记录原始读数、单位、仪器不确定度和定性变化,对同一仪器保持小数位数一致。
For databases, keep the source, conditions, and filtering choices; for sensors, record the calibration and sampling settings.
使用数据库时,保留来源、条件和筛选方式;使用传感器时,记录校准和采样设置。
Check spreadsheet formulae and units, preserve provenance, and distinguish simulated data from measurements.
检查电子表格中的公式和单位,保留数据来源,并区分模拟数据和测量数据。
For a value x plus or minus u x, the absolute uncertainty has the same unit as x.
对于 x 正负 u x,绝对不确定度与 x 的单位相同。
The fractional uncertainty is u x divided by the magnitude of x.
相对不确定度是 u x 除以 x 的绝对值。
And the percentage uncertainty multiplies that fraction by 100: a titre of 22.50 plus or minus 0.10 cubic centimetres has a 0.44 percent uncertainty.
百分比不确定度则将这个比值乘以 100:22.50 正负 0.10 立方厘米 的滴定体积,其百分比不确定度为 0.44 %。
Percentage disagreement with a reference is a different calculation, and can reflect systematic bias.
与参考值的百分比差异是另一种计算,可能反映系统偏差。
These invented values illustrate three different denominators.
这些虚构数值展示了三种不同的分母。
The measured mass is 10.40 plus or minus 0.10 grams, with accepted reference 10.00 grams.
测得质量为 10.40 正负 0.10 克,公认参考值为 10.00 克。
Percentage uncertainty divides 0.10 by 10.40 and multiplies by 100, giving 0.96 percent.
百分比不确定度用 0.10 除以 10.40 再乘以 100,得到 0.96 %。
The magnitude of percentage error divides the absolute disagreement, 0.40, by the reference 10.00, giving 4.0 percent.
百分比误差的绝对值用绝对差值 0.40 除以参考值 10.00,得到 4.0 %。
If instead the two numbers are comparable measurements without a reference role, a common symmetric percentage difference divides their difference by their mean, 10.20, giving 3.92 percent.
如果这两个数是可比较的测量值,而没有一个作为参考值,一种常见的对称百分比差异算法是用它们的差除以平均值 10.20,得到 3.92 %。
State the convention.
要说明采用的约定。
Small uncertainty does not establish accuracy.
不确定度小不能证明准确度高。
Choose one propagation convention.
选择一种不确定度传播的约定。
For small uncertainties, a conservative estimate adds absolute uncertainties for addition and subtraction, and adds fractional or percentage uncertainties for products and quotients.
对于较小的不确定度,保守估计是在加减运算中将绝对不确定度相加,在乘除运算中将相对或百分比不确定度相加。
An exact coefficient scales the absolute uncertainty, but not the fractional one.
精确系数会按比例改变绝对不确定度,但不改变相对不确定度。
And consider shared errors: a constant zero offset can cancel in a difference.
还要考虑共同误差:恒定的零点偏移在求差时可能抵消。
In invented data, a stock of 0.2000 moles per cubic decimetre, with a 0.50 percent uncertainty, is diluted using a 25.00 plus or minus 0.03 cubic centimetre pipette, into a 250.0 plus or minus 0.15 cubic centimetre flask.
在一组虚构数据中,用 25.00 正负 0.03 立方厘米 的移液管移取浓度为 0.2000 摩尔每立方分米、不确定度为 0.50 % 的储备液,在 250.0 正负 0.15 立方厘米 的容量瓶中稀释。
The concentration is 0.2000 times 25.00 over 250.0: 0.02000 moles per cubic decimetre.
浓度为 0.2000 乘以 25.00 再除以 250.0,即 0.02000 摩尔每立方分米。
The maximum percentage uncertainty is 0.50, plus 0.12, plus 0.06: 0.68 percent.
最大百分比不确定度为 0.50 加 0.12 加 0.06,即 0.68 %。
So the absolute uncertainty is about 0.00014: report 0.02000 plus or minus 0.00014.
所以绝对不确定度约为 0.00014:报告为 0.02000 正负 0.00014。
In an invented one-to-one titration, 25.00 plus or minus 0.03 cubic centimetres of sodium hydroxide needs a titre of 22.50 plus or minus 0.10 of hydrochloric acid, at 0.1000 moles per cubic decimetre, with a 0.20 percent uncertainty.
在一个虚构的 1 比 1 滴定中,25.00 正负 0.03 立方厘米 的氢氧化钠溶液需要 22.50 正负 0.10 的盐酸滴定体积,盐酸浓度为 0.1000 摩尔每立方分米,不确定度为 0.20 %。
The sodium hydroxide concentration is the acid's concentration times its volume, over the alkali's volume: 0.09000.
氢氧化钠的浓度等于盐酸浓度乘以盐酸体积,再除以碱的体积,得到 0.09000。
The maximum percentage uncertainty is 0.20, plus 0.44, plus 0.12: about 0.76 percent.
最大百分比不确定度为 0.20 加 0.44 加 0.12,约为 0.76 %。
So the result is 0.0900 plus or minus 0.0007 moles per cubic decimetre.
所以结果为 0.0900 正负 0.0007 摩尔每立方分米。
For an invented calibration graph, draw the best-fit line, and the steepest and shallowest lines.
对于一个虚构的校准图,画出最佳拟合直线、最陡直线和最平缓直线。
All three must be consistent with the full dataset, passing through every error bar.
三条直线都必须与整个数据集一致,穿过每一个误差棒。
The best-fit model is A equals 5.00 c plus 0.020, with concentration in moles per cubic decimetre, and absorbance dimensionless.
最佳拟合模型为 A 等于 5.00 c 加 0.020,其中浓度的单位为 摩尔每立方分米,吸光度无量纲。
The steepest line gives 0.440 minus 0.100, over 0.080 minus 0.020: 5.67 cubic decimetres per mole.
最陡直线给出 0.440 减去 0.100,再除以 0.080 减去 0.020,得到 5.67 立方分米每摩尔。
The shallowest gives 0.400 minus 0.140, over the same interval: 4.33.
最平缓直线给出 0.400 减去 0.140,再除以相同的区间,得到 4.33。
The gradient's units come from the axes.
斜率的单位由坐标轴的单位决定。
And check the intermediate bars too: two extreme endpoint choices alone are not enough.
还要检查中间的误差棒:仅选择两个极端端点是不够的。
The gradient is about the midpoint of the extremes: 5.00 cubic decimetres per mole.
斜率约为两个极值的中点,即 5.00 立方分米每摩尔。
Its uncertainty is about half the range: 0.67.
其不确定度约为极差的一半,即 0.67。
This range reflects the stated bars and the straight-line model; it is not a formal statistical confidence interval.
这个范围反映了所给误差棒和直线模型,并不是正式的统计置信区间。
Consider invented calibration fits with an intercept, compared on the same response dataset.
考虑对同一组响应数据进行比较的虚构带截距校准拟合。
R squared of 0.81 means the model accounts for 81 percent of variation in the measured response; 19 percent remains in residual variation.
R 的平方为 0.81,表示模型解释了测量响应中 81 % 的变异;19 % 留在残差变异中。
A second model reporting 0.94 accounts for more response variation in these data.
第二个模型报告的值为 0.94,说明它解释了这组数据中更多的响应变异。
Neither number says what percentage of readings are accurate, or what percentage was caused by concentration.
这两个数都不能说明多少百分比的读数是准确的,也不能说明多少百分比由浓度引起。
Inspect the model form, residual pattern and possible calibration bias.
要检查模型形式、残差模式和可能的校准偏差。
A higher R squared alone does not validate the measurement method.
仅凭更高的 R 的平方不能验证测量方法。
Use labelled axes and a suitable scale.
标注坐标轴并使用合适的刻度。
A gradient needs widely separated points on the fitted line, and units; a tangent gives an instantaneous gradient, and a chord an average.
求斜率时,要使用拟合直线上相距较远的点,并写出单位;切线给出瞬时斜率,割线给出平均斜率。
A nonzero intercept can indicate a blank signal, an offset, or an incomplete model: investigate it, rather than forcing the line through zero.
非零截距可能表示空白信号、偏移或模型不完整:要调查原因,而不是强行让直线通过零点。
And a high R squared does not prove accuracy or causation.
高 R 的平方不能证明准确性或因果关系。
Inspect the residuals and the chemical plausibility; interpolation and extrapolation have different evidential support.
检查残差和化学上的合理性;内插和外推所获得的证据支持程度不同。
For higher level: the uncertainty in a power.
高级程度内容:幂运算中的不确定度。
For an exact exponent n, and a small uncertainty, the fractional uncertainty in y is about the absolute value of n times the fractional uncertainty in x.
对于精确的指数 n 和较小的不确定度,y 的相对不确定度约为 x 的相对不确定度乘以 n 的绝对值。
For an invented cube, with an edge of 2.00 plus or minus 0.02 centimetres, the volume is 8.00 cubic centimetres.
对于一个虚构的立方体,边长为 2.00 正负 0.02 厘米,体积为 8.00 立方厘米。
Its fractional uncertainty is about 3 times 0.02 over 2.00: 0.030, so 0.24 cubic centimetres.
其相对不确定度约为 3 乘以 0.02 除以 2.00,即 0.030,因此绝对不确定度为 0.24 立方厘米。
Report 8.00 plus or minus 0.24.
报告为 8.00 正负 0.24。
This is a first-order estimate, not the exact cubed bounds.
这是一阶估计,而不是精确的立方上下界。
An exponential model, c equals c nought e to the minus k t, becomes a straight line: ln of c over c nought equals minus k t.
指数模型 c 等于 c₀ 乘以 e 的负 k t 次方,可以转化成一条直线:c 与 c₀ 之比的自然对数等于负 k t。
With invented values of c nought equal to 0.1000 moles per cubic decimetre, and k equal to 0.0200 per second, at 30.0 seconds, c is 0.1000 times e to the minus 0.600: 0.0549.
设虚构值 c₀ 等于 0.1000 摩尔每立方分米,k 等于 0.0200 每秒,在 30.0 秒时,c 等于 0.1000 乘以 e 的负 0.600 次方,即 0.0549。
The half-time is ln 2 over k: 34.7 seconds, and the transformed gradient is minus k.
半衰期为 ln 2 除以 k,即 34.7 秒,变换后直线的斜率为负 k。
A straight transformed plot supports the model over the tested range; it does not establish a mechanism by itself.
变换后的图像为直线支持模型在测试范围内成立;但它本身不能确定反应机理。
The conclusion must answer the research question.
结论必须回答研究问题。
Use processed data and uncertainty to state a supported trend, and separate the observation from its chemical explanation.
利用处理后的数据和不确定度说明有证据支持的趋势,并将观察结果与其化学解释分开。
Then build each evaluation point from cause to improvement.
然后每个评价点都要从原因联系到改进措施。
A small titre gives a large percentage reading uncertainty: a suitable larger aliquot may reduce it, within approved limits.
较小的滴定体积会产生较大的百分比读数不确定度:在允许范围内,适当增大移取体积可能降低它。
Heat loss biases calorimetry: insulation, or an appropriate time-series correction, addresses it; repetition alone does not remove the bias.
热损失会使量热结果产生偏差:隔热或适当的时间序列校正可以解决这个问题;仅靠重复不能消除偏差。
An anomaly needs a reasoned decision, and a record of it.
对异常值的处理需要经过合理判断并加以记录。
Inspect the raw observations and apparatus, repeat if possible, and justify including or excluding the value.
检查原始观察记录和仪器,如有可能就重复实验,并说明保留或排除该值的理由。
Do not delete a value because it weakens a trend.
不要因为一个值削弱了趋势就将它删除。
Compare with relevant references, under matching conditions, and distinguish accuracy, precision, reliability, and validity.
在相同条件下与相关参考值比较,并区分准确度、精密度、可靠性和有效性。
And limit the conclusion to the supported measurement range and the model's assumptions.
结论的范围要限制在有证据支持的测量范围和模型假设之内。
Link each weakness to its effect and an improvement.
将每个缺陷与其影响和改进措施联系起来。
A small titre of about five cubic centimetres gives a large percentage reading uncertainty; use a larger aliquot.
约 5 立方厘米 的小滴定体积会产生较大的百分比读数不确定度;应增大移取体积。
Heat lost to the surroundings makes the temperature change too small, so the enthalpy change is underestimated; insulate the calorimeter better.
向环境散失的热量使温度变化偏小,从而低估焓变;应加强量热器的隔热。
Now try two.
现在试做两题。
A container reads 6.237 plus or minus 0.001 grams before a transfer, and 2.104 plus or minus 0.001 after: find the transferred mass, and its conservative uncertainty.
一个容器在转移前的读数为 6.237 正负 0.001 克,转移后为 2.104 正负 0.001,求转移的质量及其保守估计的不确定度。
Separately, use A equals 5.00 c plus 0.020 to find the concentration when A is 0.270.
另用 A 等于 5.00 c 加 0.020,求 A 为 0.270 时的浓度。
What happens if you ignore the intercept?
如果忽略截距,会发生什么?
Pause and work them out before the answer.
请暂停,自己算出答案。
The mass transferred is 6.237 minus 2.104: 4.133 grams, with an uncertainty of 0.001 plus 0.001: 0.002 grams.
转移的质量为 6.237 减去 2.104,即 4.133 克,不确定度为 0.001 加 0.001,即 0.002 克。
From the calibration, c is 0.270 minus 0.020, over 5.00: 0.0500 moles per cubic decimetre.
根据校准关系,c 等于 0.270 减去 0.020,再除以 5.00,即 0.0500 摩尔每立方分米。
Ignoring the intercept would assign the background absorbance to the analyte, and overestimate the concentration.
忽略截距会把背景吸光度归给待测物,从而高估浓度。
Then attempt the handout questions on techniques, measurement, and model evaluation.
然后尝试讲义中关于实验技术、测量和模型评价的题目。
Finally: every number needs a measurement model.
最后:每个数字都需要一个测量模型。
Is it a reading, or a difference?
它是一个读数,还是一个差值?
Is the uncertainty absolute, or a percentage?
不确定度是绝对值还是百分比?
State your uncertainty convention, and keep guard digits until the final rounding.
说明采用的不确定度约定,并保留额外数字直到最后修约。
Use units in tables, on axes, and for gradients.
在表格、坐标轴和斜率中写明单位。
Close repeats and a high R squared do not prove accuracy.
重复结果接近以及 R 的平方高,并不能证明准确度高。
And for evaluation, connect the cause, the consequence, and a specific, feasible improvement; preserve the raw data, and justify any exclusions.
评价时,要将原因、后果和具体可行的改进措施联系起来;保留原始数据,并说明排除任何数据的理由。
Comments
No comments yet. Be the first to ask or share something.