You have heated Benedict's with glucose, squashed a root tip and rinsed beetroot until the water ran clear. 你曾将本尼迪克特试剂与葡萄糖一起加热,压制过根尖,并冲洗甜菜根直到水变清澈。
Unit 3 asks you to write about that work. 第 3 单元要求你以书面形式描述这些实验。
Nothing in it is new theory. 这里没有新的理论知识。
When a question says justify, pair every step with the reason it makes the data valid. 当题目要求论证时,要说明每一步为什么能使数据有效。
Rinsing beetroot removes pigment from the cut surfaces, so the absorbance measures membrane leakage, not slicing damage. 冲洗甜菜根可以去除切面上的色素,因此吸光度测量的是细胞膜泄漏的色素,而不是切割损伤造成的色素释放。
The independent variable is what you change, such as alcohol concentration. 自变量是你改变的因素,例如酒精浓度。
The dependent variable is what you measure, such as the absorbance of leaked pigment. 因变量是你测量的量,例如泄漏色素的吸光度。
Everything else is a control variable, kept the same with a reason. 其他因素都是控制变量,要保持不变并说明原因。
Temperature, for example, changes membrane fluidity. 例如,温度会改变细胞膜的流动性。
A control treatment leaves out the change, water instead of alcohol, so any difference can be put down to the independent variable alone. 对照处理不施加所研究的变化,例如用水代替酒精,这样任何差异都可以归因于自变量本身。
Repeat readings make a result more reliable, give a mean, and let you estimate the spread with a standard deviation or error bars. 重复测量可以提高结果的可靠性,求出平均值,并利用标准差或误差棒估计数据的离散程度。
But they cannot remove a systematic error. 但重复测量无法消除系统误差。
A balance with a zero error shifts every reading the same way, so the mean is wrong by the same amount, however many repeats you take. 存在零点误差的天平会使每次读数沿同一方向发生偏移,因此无论重复多少次,平均值都会产生相同大小的误差。
Core practical 1 matches colours against standards made by serial dilution. 核心实验 1 将颜色与连续稀释制成的标准液进行比对。
Practical 2 titrates DCPIP against vitamin C. 实验 2 用维生素 C 滴定 DCPIP。
Practical 3 measures beetroot pigment with a colorimeter, and 4 finds an enzyme's initial rate. 实验 3 用比色计测量甜菜根色素,实验 4 测定酶促反应的初始速率。
Practicals 5 and 7 are microscopy and plant sections, 6 is the root-tip squash, 8 tests fibre strength, and 9 measures zones of inhibition around plant extracts. 实验 5 和 7 涉及显微观察和植物切片,实验 6 是根尖压片,实验 8 测试纤维强度,实验 9 测量植物提取物周围的抑菌圈。
Cut the last four to five millimetres of the root, where cells divide. 切取根尖末端 4 到 5 毫米,那里有正在分裂的细胞。
Warm it in dilute acid to separate the cells, then rinse. 在稀酸中加热,使细胞分离,然后冲洗。
Stain the chromosomes with toluidine blue or acetic orcein. 用甲苯胺蓝或醋酸洋红给染色体染色。
Squash under a coverslip to spread a single layer of cells. 在盖玻片下压片,使细胞铺展成单层。
Then scan the slide systematically and count cells in each stage on high power. 然后有系统地扫描装片,在高倍镜下统计各阶段的细胞数。
For core practical 9, aseptic technique protects both you and the culture. 在核心实验 9 中,无菌操作既能保护你,也能保护培养物。
Work near a Bunsen updraught, flame loops and bottle necks, and open plates only briefly. 在本生灯的上升气流附近操作,用火焰灼烧接种环和瓶口,并且只短暂打开培养皿。
Tape the lid but do not seal it, so anaerobes do not thrive. 用胶带固定皿盖,但不要完全密封,以免厌氧菌大量繁殖。
Incubate upside down below 30 degrees. 在低于 30 度的温度下倒置培养。
Note that a lower temperature reduces the growth of human pathogens, but does not guarantee they cannot grow. 注意,较低温度可以减少人体病原体的生长,但不能保证它们不会生长。
To compare the vitamin C in two juices, first standardise. 要比较两种果汁中的维生素 C,首先要进行标准化。
Count the drops of one percent ascorbic acid that decolourise one cubic centimetre of DCPIP, say ten. 数出使 1 立方厘米 DCPIP 褪色所需的 1% 抗坏血酸溶液的滴数,假设是 10 滴。
Then do the same for each juice, with repeats. 然后用相同的方法分别测试每种果汁,并重复实验。
Keep the DCPIP volume and concentration the same, and use one dropper throughout, because drop size is the unit. 保持 DCPIP 的体积和浓度相同,始终使用同一个滴管,因为滴的大小是计量单位。
A juice needing only five drops is twice as concentrated, two percent. 一种果汁如果只需 5 滴,它的浓度就是两倍,即 2%。
The standard vitamin C solution is 1 percent and takes ten drops to decolourise one cubic centimetre of DCPIP. 标准维生素 C 溶液的浓度为 1%,需要 10 滴才能使 1 立方厘米 DCPIP 褪色。
The juice takes only five drops, so each drop carries twice as much vitamin C. 果汁只需要 5 滴,所以每滴含有的维生素 C 是两倍。
Its concentration is ten over five times one percent, two percent. 它的浓度为 10 除以 5 再乘以 1%,即 2%。
Choose the instrument that matches the quantity, and quote only the figures it supports. 选择与所测量的量相匹配的仪器,并且只写出仪器精度所支持的位数。
A millimetre ruler gives ± half a millimetre. 毫米刻度尺的不确定度为 ± 0.5 毫米。
For a 40 millimetre reading, that is 0.5 over 40, a 1.25 percent uncertainty. 对于 40 毫米的读数,不确定度为 0.5 除以 40,即 1.25%。
When you multiply or divide, add the percentage uncertainties; when you add or subtract, add the absolute ones. 乘除时,将百分比不确定度相加;加减时,将绝对不确定度相加。
And a trailing zero can be significant. 另外,末尾的零也可以是有效数字。
A table earns its marks by rule. 表格要按规则制作才能得分。
Head each column with the quantity and its unit, such as permeability in arbitrary units, and keep units out of the cells. 每列的表头都要写出物理量和单位,例如以任意单位表示的通透性,单元格内不要写单位。
Put the independent variable in the first column. 把自变量放在第一列。
Enter every value exactly as measured, and draw the table before you start, so nothing is squeezed in. 每个数值都要按测量结果原样填写,并在开始实验前画好表格,这样就不会出现内容挤不下的情况。
Choose the graph from the independent variable. 根据自变量选择图表。
Four named liquids are categories, so draw a bar chart with gaps between the bars. 四种有名称的液体属于类别数据,所以要画柱状图,柱子之间留有间隙。
Time over twenty hours is continuous, so draw a line graph with a smooth best-fit line or curve. 20 小时内的时间是连续变量,所以要画折线图,并画出平滑的最佳拟合直线或曲线。
Either way, put the independent variable on the x-axis, label both axes with quantity and unit, use most of the grid, and plot each point as a sharp cross. 无论哪种图,都要把自变量放在 x 轴,两轴都标明量和单位,充分利用坐标纸,并用清晰的十字标出每个数据点。
A gradient comes from a large triangle drawn on the best-fit line, at least half the line's length. 求斜率时,要在最佳拟合线上画一个大三角形,其长度至少为拟合线长度的一半。
Divide the change in y by the change in x, and divide the units too. 用 y 的变化量除以 x 的变化量,单位也要相除。
With error bars, the steepest and shallowest lines that still pass through the bars show how uncertain the gradient is. 有误差棒时,仍能穿过误差棒的最陡和最平缓的直线可以显示斜率的不确定程度。
Read values off the line, not off a data point. 要从线上读取数值,而不是直接使用某个数据点。
Percentage change divides by the initial value. 计算百分比变化时,要除以初始值。
Percentage difference, the 2025 formula, divides by the mean of the two values. 计算百分比差异时,按 2025 年的公式,要除以两个数值的平均值。
For cassava regions of 33.65 and 29.64, the difference is 4.01, the mean 31.645, and the percentage difference 12.67 percent. 对于 33.65 和 29.64 的木薯区域数值,差为 4.01,平均值为 31.645,百分比差异为 12.67%。
Writing 12.70 is wrong rounding, not a wrong zero. 写成 12.70 是舍入错误,而不是末尾零的错误。
And 80 percent of 98 cells is 78.4, reported as 78 cells, because there is no 0.4 of a cell. 98 个细胞的 80% 是 78.4,报告时写成 78 个细胞,因为不存在 0.4 个细胞。
An anomalous result is far from the pattern. 异常结果是明显偏离总体规律的结果。
Check it by repeating that treatment; never delete it silently. 要对该处理重复实验来检查,绝不能不作说明就删除它。
Name realistic improvements. 提出切实可行的改进方法。
A colorimeter instead of colour matching makes the result quantitative. 用比色计代替目测比色,可以得到定量结果。
Zeroing on plain solvent removes an offset. 用纯溶剂调零可以消除零点偏移。
More values inside the range narrow the interpolation, and repeats give a standard deviation and error bars. 在测量范围内增加取值可以缩小插值区间,重复测量则可以得到标准差和误差棒。
To study variation between organisms, measure different individuals. 要研究生物个体之间的变异,就要测量不同的个体。
And conclude only within the range you measured. 最后,只能在测量范围内得出结论。
This unit examines written practical skills. 本单元考查的是书面实验技能。
Full marks do not show that you kept a culture clean, focused a microscope patiently, or squashed a root tip without smearing it. 拿到满分并不能说明你在培养过程中保持了无菌,耐心地调好了显微镜焦距,或者压制根尖时没有把它弄成一片模糊。
That experience is built in class during Units 1 and 2. 这些经验是在 Units 1 和 2 的课堂上积累的。
Practise the real practicals, then describe them. 先动手练习真正的实验,再描述它们。
Check yourself. 自我检测一下。
The solvent-only seedlings are a control, so any change can be put down to trifluralin. 只用溶剂处理的幼苗是对照,因此任何变化都可以归因于氟乐灵。
Eighty percent of 98 is 78.4, so 78 cells. 98 的 80% 是 78.4,所以是 78 个细胞。
Four liquids need a bar chart, and time needs a line graph. 四种液体需要用柱状图,时间则需要用折线图。
Repeats improve reliability and estimate spread, but cannot remove a systematic error. 重复测量能提高可靠性并估计离散程度,但无法消除系统误差。
And 12.6718 rounds to 12.67, not 12.70. 12.6718 舍入后为 12.67,不是 12.70。