| English | 释义 | 拼音 |
|---|---|---|
| systematic error/ˌsɪstəˈmætɪk ˈerə/ | 系统误差 | xì tǒng wù chā |
| random error/ˈrændəm ˈerə/ | 随机误差 | suí jī wù chā |
| zero error/ˈzɪərəʊ ˈerə/ | 零点误差 | líng diǎn wù chā |
| uncertainty/ʌnˈsɜːtənti/ | 不确定度 | bù què dìng dù |
| absolute uncertainty/ˈæbsəluːt ʌnˈsɜːtənti/ | 绝对不确定度 | jué duì bù què dìng dù |
| percentage uncertainty/pəˈsentɪdʒ ʌnˈsɜːtənti/ | 百分比不确定度 | bǎi fēn bǐ bù què dìng dù |
| error bar/ˈerə bɑː/ | 误差棒 | wù chā bàng |
| line of best fit/laɪn ɒv best fɪt/ | 最佳拟合线 | zuì jiā nǐ hé xiàn |
| gradient/ˈɡreɪdɪənt/ | 斜率 | xié lǜ |
| model/ˈmɒdl/ | 模型 | mó xíng |
Faster than light? OPERA, 2011
- In September 2011 the OPERA experiment reported neutrinos arriving from CERN in Italy 60 ns earlier than light would. The team asked other scientists to find the mistake.
- In February 2012 they found it: a loose fibre-optic cable in the timing system. It was a systematic error 系统误差, and a claim that broke physics turned out to be a measurement problem.
Random and systematic errors
- A random error 随机误差 scatters readings both ways — reaction time on a stopwatch, a fluctuating meter. Repeating and taking a mean reduces its effect.
- A systematic error shifts every reading the same way — a balance that reads 0.2 g with nothing on it (a zero error 零点误差), or a loose cable. Repeats do not remove it; you must find and correct the cause.
A balance reads 0.3 g with nothing on it. What kind of error is this?
难度 1/5 · 今日首次完成可获 100 金币及少量额外奖励
It shifts every reading by the same 0.3 g. Subtract it from each reading or re-zero the balance.
Stating uncertainty
- Absolute uncertainty 绝对不确定度 is in the units of the reading: 25.0 ± 0.1 g. From repeats, use half the range: 15.2, 15.6 and 15.4 s give $15.4 \pm 0.2$ s.
- Percentage uncertainty 百分比不确定度 $= \dfrac{\text{absolute}}{\text{value}} \times 100\,\%$. When values are added or subtracted, add absolute uncertainties; when multiplied or divided, add percentages; a square doubles the percentage.
Three readings are 4.2 s, 4.6 s and 4.4 s. What is the absolute uncertainty in the mean, in s?
难度 2/5 · 今日首次完成可获 140 金币及少量额外奖励
The range is 4.6 − 4.2 = 0.4 s, and half the range is 0.2 s.
A length is $2.00 \pm 0.05$ m. What is the percentage uncertainty?
难度 2/5 · 今日首次完成可获 140 金币及少量额外奖励
$\dfrac{0.05}{2.00} \times 100 = 2.5\,\%$.
Worked example: the density of a stone
A stone has mass $25.0 \pm 0.1$ g and volume $10.0 \pm 0.5\ \text{cm}^3$. Find its density with its uncertainty.
- Value: $\rho = \dfrac{m}{V} = \dfrac{25.0}{10.0} = 2.50\ \dfrac{\text{g}}{\text{cm}^3}$.
- Percentages: mass $\dfrac{0.1}{25.0} \times 100 = 0.4\,\%$; volume $\dfrac{0.5}{10.0} \times 100 = 5\,\%$. A quotient adds them: $5.4\,\%$.
- Result: $5.4\,\%$ of 2.50 is 0.135, so $\rho = 2.50 \pm 0.14\ \dfrac{\text{g}}{\text{cm}^3}$. The volume dominates: a better measuring cylinder would help most.
测量范围与商的不确定度估计
50 ± 1 mm的百分比不确定度为2%。与100 ± 3 mm的读数比较:商的百分比不确定度相加估计为5%,而精确端点计算给出略不对称的范围。
The side of a square is $5.0 \pm 0.1$ cm. What is the percentage uncertainty in its area?
难度 2/5 · 今日首次完成可获 140 金币及少量额外奖励
The side has $\dfrac{0.1}{5.0} \times 100 = 2\,\%$. Area is side × side, so the percentages add: 4 %.
Graphs and error bars
- Plot each mean with an error bar 误差棒 showing its uncertainty, then draw one straight line of best fit 最佳拟合线 with points spread evenly on both sides.
- Find the gradient 斜率 from a large triangle: $\dfrac{\Delta y}{\Delta x}$. In the figure, the line goes through (0, 0) and (4, 8), so the gradient is $\dfrac{8}{4} = 2.0$.
A line of best fit passes through (0.5, 1.0) and (4.0, 8.0). What is its gradient?
难度 2/5 · 今日首次完成可获 140 金币及少量额外奖励
$\dfrac{8.0 - 1.0}{4.0 - 0.5} = \dfrac{7.0}{3.5} = 2.0$.
Uncertainty in a gradient
- Draw the steepest and the shallowest lines that still pass through every error bar. If they have gradients 2.3 and 1.8, the gradient is $2.0 \pm 0.25$, about $2.0 \pm 0.3$.
- The percentage uncertainty of the gradient is then $\dfrac{0.25}{2.0} \times 100 \approx 13\,\%$, and it carries into any quantity calculated from it.
The steepest line through the error bars has gradient 3.6 and the shallowest has gradient 3.0. What is the uncertainty in the gradient?
难度 2/5 · 今日首次完成可获 140 金币及少量额外奖励
Half the difference between the two lines: $\dfrac{3.6 - 3.0}{2} = 0.3$.
Testing a model
- A model 模型 such as $y \propto x$ predicts a straight line through the origin. In the figure every error bar touches the line, so the data are consistent with the model.
- "Consistent" does not mean proved. If the best line misses the origin by more than the uncertainty, look for a systematic error or a wrong model, as the OPERA team did.
Which of these reduce the effect of random error?
难度 2/5 · 今日首次完成可获 140 金币及少量额外奖励
Averaging and measuring a larger quantity shrink random scatter. The last two correct systematic errors.
If a straight line through the origin passes through every error bar, the data prove that $y \propto x$.
难度 1/5 · 今日首次完成可获 100 金币及少量额外奖励
The data are consistent with the model. Better measurements could still show a curve or an intercept.
"More repeats remove all error" is wrong. Repeats average out random error only. A zero error or a slow stopwatch shifts every repeat the same way, so the mean is just as wrong; you must recalibrate or correct the readings.
Every measurement carries an uncertainty: half the range for repeats, and percentages added for products and quotients. On a graph, error bars and steepest/shallowest lines give the gradient's uncertainty, and a model is supported only if the line fits within the error bars.
A student finds $g$ from a gradient: $9.6 \pm 0.4\ \dfrac{\text{m}}{\text{s}^2}$. The accepted value is $9.81\ \dfrac{\text{m}}{\text{s}^2}$. Is the result consistent, and how could the uncertainty be reduced?
Compare with the accepted value through the uncertainty, not just the difference.